Configured for safety and process control in the Modicon M580 platform, the Schneider Electric BMEP584040S (BMEP584040S processor module) provides processor execution, Ethernet device communication, local and remote I/O management, and CIP Safety device processing. It supports up to 8 racks, 16 remote I/O stations, 64 distributed devices, and 64 CIP Safety I/O devices.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | BMEP584040S |
| Brand | Schneider Electric |
| Series | Modicon M580 |
| Product Type | Processor module |
| Origin | US |
| Weight | 0.849 kg |
| Dimensions | 9.921 x 7.008 x 3.504 in (package dimensions) |
| Operating Temp | -25 to 60 deg C |
| Storage Temp | -40 to 85 deg C |
| Power Consumption | 295 mA at 24 VDC |
| Supply | Internal power supply via rack |
| Rack Capacity | 8 racks |
| Local Discrete I/O | 4096 I/O |
| Local Analog I/O | 1024 I/O |
| Local Application-Specific Channels | 144 |
| Remote I/O Stations | 16 |
| Distributed Equipment | 64 |
| CIP Safety I/O Devices | 64 |
| Ethernet Connections | 1 service port + 2 device network ports |
| USB Connection | 1 USB mini-B |
| Program Memory | 16 MB |
| Data Memory | 2048 kB |
| Safety Program Memory | 4 MB |
| Safety Data Memory | 1024 kB |
| Flash Storage | 4 GB |
| Instruction Processing | 30 Kinst/ms at 65% Boolean + 35% fixed arithmetic; 40 Kinst/ms at 100% Boolean |
| Communication Services | RIO scanner, DIO scanner |
| Communication Module Capacity | 16 AS-Interface modules, 4 Ethernet communication modules |
| Protection Rating | IP20 |
| Protective Treatment | Conformal coated |
| Vibration Resistance | 3 gn |
| Shock Resistance | 15 gn |
| Relative Humidity | 5 to 95% at 55 deg C, non-condensing |
| Operating Altitude | 0 to 2000 m; 2000 to 5000 m with derating |
| Safety Level | SIL 3 IEC 61508/IEC 61511; SILCL 3 IEC 62061 and ISO 13849-1 Category 4; SIL 4 EN 50126/EN 50128/EN 50129 |
| Certifications | CE, UL, CSA, RCM, EAC, ATEX Zone 2/22, IECEx Zone 2/22, TÜV, UKCA |
| Cybersecurity Functions | DoS prevention, IPSec, SNMP logging, Syslog, audit trail, embedded firewall, firmware signature, password protection, port hardening |
M580 Ethernet and I/O Processing
The BMEP584040S uses Ethernet TCP/IP interfaces for service and device-network communication. The processor manages RIO and DIO scanning and supports distributed equipment and CIP Safety I/O devices. Local processing capacity is specified at 4096 discrete I/O and 1024 analog I/O, with up to 144 application-specific local channels.
Application-specific functions include counter processing, motion control, SSI encoder interfaces, accurate time stamping, serial links, and HART communication. The processor provides separate program, process data, safety program, and safety data memory areas.
Frequently Asked Questions
Q: How is the BMEP584040S powered?
A: The module receives its operating power through the Modicon M580 rack backplane. The specified current consumption is 295 mA at 24 VDC.
Q: What Ethernet connections are provided?
A: The processor has one Ethernet TCP/IP service port and two Ethernet TCP/IP device-network ports. A USB mini-B interface is also provided for integrated connections.
Q: What I/O and safety device capacity is specified?
A: The processor supports up to 4096 local discrete I/O, 1024 local analog I/O, 16 remote I/O stations, 64 distributed devices, and 64 CIP Safety I/O devices.
Field Installation Guidelines
- Install the processor in the specified Modicon M580 rack position and verify correct mechanical engagement with the backplane.
- Confirm that the rack power system can supply the processor and all connected modules within the applicable load limits.
- Route Ethernet communication wiring separately from high-current switching and power conductors where practical to reduce electromagnetic coupling.
- Terminate cable shields according to the applicable M580 installation and plant grounding design. Avoid creating unintended shield current paths.
- Verify Ethernet port assignment before connecting service and device-network cables.
- Check RUN, ERR, I/O, DL, BACKUP, Ethernet, SRUN, SMOD, and FORCED IO indicators during commissioning.
- Use the specified environmental limits when locating the rack. The module is IP20 and requires an enclosure providing the required environmental protection.
- For safety applications, verify the configured safety architecture, firmware compatibility, wiring, diagnostics, and safety validation procedure against the applicable M580 safety documentation before placing the system into service.
การชำระเงิน: T/T, Western Union
ท่าเรือขนส่ง: เซี่ยเหมิน
ระยะเวลาดำเนินการ: โดยทั่วไป 1–3 วันทำการหลังยืนยันการชำระเงิน (ขึ้นอยู่กับสินค้าในสต็อก)
จัดส่งทั่วโลก: เราจัดส่งชิ้นส่วนระบบอัตโนมัติทางอุตสาหกรรมให้แก่ลูกค้าทั่วโลก โดยจะแจ้งค่าขนส่งพร้อมใบขอใบเสนอราคาของคุณ
คำถามที่พบบ่อย
คำถามที่พบบ่อยเกี่ยวกับใบเสนอราคา การจัดส่ง การรับประกัน และการคืนสินค้าคลิก ขอใบเสนอราคา ในหน้าสินค้า แล้วส่งหมายเลขชิ้นส่วน จำนวนที่ต้องการ และประเทศปลายทางให้เรา ทีมฝ่ายขายของเราจะตอบกลับพร้อมข้อมูลสินค้าที่มีจำหน่าย ราคา และระยะเวลาจัดส่งโดยประมาณ
สินค้าที่มีอยู่ในสต็อกโดยปกติจะจัดเตรียมหลังจากได้รับการชำระเงินและยืนยันคำสั่งซื้อแล้ว คำสั่งซื้อส่วนใหญ่จัดส่งจากคลังสินค้าของเราในประเทศจีน แต่สถานที่จัดส่งอาจแตกต่างกันไปตามสต็อกปัจจุบัน
ใช่ เราจัดส่งชิ้นส่วนระบบอัตโนมัติทางอุตสาหกรรมให้ลูกค้าทั่วโลก ค่าจัดส่งและระยะเวลาในการขนส่งขึ้นอยู่กับปลายทาง น้ำหนักพัสดุ ขนาดสินค้า และข้อกำหนดการนำเข้าของท้องถิ่น
เราใช้บริการ DHL, FedEx, UPS และบริษัทขนส่งระหว่างประเทศอื่น ๆ เป็นประจำ โดยสามารถเลือกผู้ให้บริการขนส่งได้ตามปลายทาง ความเร็วในการจัดส่ง ขนาดของพัสดุ และความต้องการของลูกค้า
โดยทั่วไป สินค้าของเราครอบคลุมการรับประกัน 12 เดือน สินค้าที่มีสิทธิ์ยังสามารถส่งคืนได้ภายใต้นโยบายคืนเงินภายใน 30 วัน โปรดติดต่อทีมงานของเราก่อนส่งคืนสินค้าใด ๆ เพื่อยืนยันข้อกำหนดที่ใช้บังคับและคำแนะนำในการส่งคืน
คุณอาจชอบสิ่งเหล่านี้ด้วย
บทความในบล็อก
ข่าวสารระบบอัตโนมัติในภาคอุตสาหกรรม คู่มือด้านเทคนิค และอัปเดตผลิตภัณฑ์