Overview

The 8440-1868 from Woodward is a microprocessor-controlled Automatic Transfer Switch (ATS) controller engineered to manage reliable power source switching in three-phase electrical systems. The unit supervises and controls transfer operations between utility power, generator sources, or multiple generator sets while maintaining system stability.

Designed for mission-critical installations, this controller supports several transfer strategies—including open, delayed, and closed transitions—combined with phase-synchronization monitoring. These functions enable smooth source transfers while minimizing voltage disturbances, current spikes, and mechanical stress on connected equipment.

Technical Specifications

Parameter Specification
Model DTSC-200-55B (8440-1868)
Manufacturer Woodward
Device Type Automatic Transfer Switch (ATS) Controller
System Compatibility Three-phase AC power systems
Transfer Modes Open transition, delayed transition, closed transition
Synchronization Method In-phase monitoring with synch-check logic
Closed Transition Overlap Adjustable from <100 ms to continuous paralleling
Current Input Rating 5 A CT input
Control Architecture Microprocessor-based digital controller
Programmable Functions Source selection, transfer inhibit, load shed/restore
Test Functions Engine test sequences and operational diagnostics
Auxiliary Control Elevator pre-signal capability
Protection & Monitoring Voltage and phase monitoring for both sources
Installation Type Panel-mounted ATS control interface
Typical System Voltage Configurable depending on ATS system design

Key Functional Capabilities

Multi-Mode Transfer Control Supports three transfer strategies to suit different electrical system requirements. Open transition ensures safe break-before-make operation, while closed transition allows seamless source changeover with minimal interruption.

In-Phase Synchronization Monitoring Built-in synch-check logic verifies voltage, frequency, and phase alignment before initiating closed transition transfers, reducing electrical stress and transient disturbances.

Adjustable Closed-Transition Timing Overlap timing can be configured from momentary transfers (<100 ms) to extended parallel operation, supporting complex power management strategies.

Programmable Load Management Integrated load shedding and restoration logic allows staged reconnection of loads following generator startup or power restoration.

Flexible System Integration Customizable inputs and outputs support features such as transfer inhibit commands, external source selection, elevator pre-signal control, and scheduled generator testing.

Typical Application Scenarios

The DTSC-200-55B controller is commonly implemented in critical power systems where uninterrupted operation is required:

  • Data centers and telecommunications infrastructure
  • Hospitals and medical facilities
  • Industrial manufacturing plants
  • Commercial buildings and high-rise complexes
  • Marine and offshore power systems
  • Utility backup generator installations

Operational Considerations

Correct configuration and commissioning are essential to ensure reliable transfer operation. The controller must be matched with the appropriate ATS hardware, voltage sensing configuration, and current transformer ratings. Routine functional testing is recommended to confirm transfer logic and protection responses.

FAQ

What type of transfer systems can the DTSC-200-55B manage? The controller is designed for three-phase ATS installations and can control transfers between utility power, generator sets, or multiple generator sources.

Does the controller support closed transition transfers? Yes. The controller includes synch-check logic and adjustable overlap timing to enable safe make-before-break transfers.

Can the controller perform generator test routines? Built-in engine test programs allow scheduled generator testing without disrupting facility power.

การชำระเงิน: T/T, Western Union

ท่าเรือขนส่ง: เซี่ยเหมิน

ระยะเวลาดำเนินการ: โดยทั่วไป 1–3 วันทำการหลังยืนยันการชำระเงิน (ขึ้นอยู่กับสินค้าในสต็อก)

จัดส่งทั่วโลก: เราจัดส่งชิ้นส่วนระบบอัตโนมัติทางอุตสาหกรรมให้แก่ลูกค้าทั่วโลก โดยจะแจ้งค่าขนส่งพร้อมใบขอใบเสนอราคาของคุณ

คำถามที่พบบ่อย

คำถามที่พบบ่อยเกี่ยวกับใบเสนอราคา การจัดส่ง การรับประกัน และการคืนสินค้า

คลิก ขอใบเสนอราคา ในหน้าสินค้า แล้วส่งหมายเลขชิ้นส่วน จำนวนที่ต้องการ และประเทศปลายทางให้เรา ทีมฝ่ายขายของเราจะตอบกลับพร้อมข้อมูลสินค้าที่มีจำหน่าย ราคา และระยะเวลาจัดส่งโดยประมาณ

สินค้าที่มีอยู่ในสต็อกโดยปกติจะจัดเตรียมหลังจากได้รับการชำระเงินและยืนยันคำสั่งซื้อแล้ว คำสั่งซื้อส่วนใหญ่จัดส่งจากคลังสินค้าของเราในประเทศจีน แต่สถานที่จัดส่งอาจแตกต่างกันไปตามสต็อกปัจจุบัน

ใช่ เราจัดส่งชิ้นส่วนระบบอัตโนมัติทางอุตสาหกรรมให้ลูกค้าทั่วโลก ค่าจัดส่งและระยะเวลาในการขนส่งขึ้นอยู่กับปลายทาง น้ำหนักพัสดุ ขนาดสินค้า และข้อกำหนดการนำเข้าของท้องถิ่น

เราใช้บริการ DHL, FedEx, UPS และบริษัทขนส่งระหว่างประเทศอื่น ๆ เป็นประจำ โดยสามารถเลือกผู้ให้บริการขนส่งได้ตามปลายทาง ความเร็วในการจัดส่ง ขนาดของพัสดุ และความต้องการของลูกค้า

โดยทั่วไป สินค้าของเราครอบคลุมการรับประกัน 12 เดือน สินค้าที่มีสิทธิ์ยังสามารถส่งคืนได้ภายใต้นโยบายคืนเงินภายใน 30 วัน โปรดติดต่อทีมงานของเราก่อนส่งคืนสินค้าใด ๆ เพื่อยืนยันข้อกำหนดที่ใช้บังคับและคำแนะนำในการส่งคืน

Products FAQs

คุณอาจชอบสิ่งเหล่านี้ด้วย