{"product_id":"schneider-electric-bmxnor0200h-modicon-x80-rtu-communication-module","title":"Schneider Electric BMXNOR0200H Modicon X80 RTU Communication Module","description":"\u003cp\u003eThe \u003cstrong\u003eBMXNOR0200H\u003c\/strong\u003e is a ruggedized RTU communication module for Schneider Electric Modicon M340 and M580 automation platforms. It supports DNP3, DNP3 IP and IEC 60870-5-101\/104 protocols, enabling communication between PLC systems, remote terminal units (RTUs) and SCADA systems. Ethernet and serial interfaces provide connectivity for network-based and modem-based communication, while the conformal coating and extended operating temperature range support installation in demanding environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Functions and Protocols\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXNOR0200H provides multiple communication services for remote monitoring and control applications. It supports both master and slave operation across multiple protocols within one module, allowing the controller to exchange data with remote RTU stations and forward events to a SCADA system.\u003c\/p\u003e\n\u003cp\u003eSupported communication functions include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDNP3 and DNP3 IP.\u003c\/li\u003e\n\u003cli\u003eIEC 60870-5-101 and IEC 60870-5-104.\u003c\/li\u003e\n\u003cli\u003eModbus\/TCP messaging.\u003c\/li\u003e\n\u003cli\u003eTimestamped event management.\u003c\/li\u003e\n\u003cli\u003eTransparent forwarding of events from remote slave devices to SCADA.\u003c\/li\u003e\n\u003cli\u003eExternal modem management through serial, fixed-line, GSM and GPRS\/3G connections.\u003c\/li\u003e\n\u003cli\u003eAutomatic event backup in the event of power failure.\u003c\/li\u003e\n\u003cli\u003eCSV data logging and storage.\u003c\/li\u003e\n\u003cli\u003eEmail and SMS notifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEthernet and Serial Interfaces\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides an Ethernet RJ45 interface supporting 10BASE-T and 100BASE-TX, together with an RJ45 serial interface supporting RS232 and RS485 communication. These interfaces allow the module to connect to Ethernet-based control networks as well as serial RTU equipment.\u003c\/p\u003e\n\u003cp\u003eThe Ethernet interface supports web services, FTP, SMTP, NTP and SNMP functions. Additional services include BootP, DHCP and FDR client functionality. The integrated web server provides Rackviewer, a data editor and support for user-defined web pages.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMemory and Module Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA 128 MB SD flash memory card, model \u003cstrong\u003eBMXRWS128MWF\u003c\/strong\u003e, is included. It supports standard web server resources, user-defined web pages and CSV data logging. Stored event and process information can be used for monitoring and data retrieval.\u003c\/p\u003e\n\u003cp\u003eThe front-panel LEDs provide operating and communication status:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eETH ACT and ETH LINK: Ethernet activity and link status.\u003c\/li\u003e\n\u003cli\u003eETH STS: Ethernet network status.\u003c\/li\u003e\n\u003cli\u003eRUN: Processor operating status.\u003c\/li\u003e\n\u003cli\u003eERR: Processor or system error.\u003c\/li\u003e\n\u003cli\u003eCARD ERR: Memory card error.\u003c\/li\u003e\n\u003cli\u003eDL: Download activity.\u003c\/li\u003e\n\u003cli\u003eSER COM: Serial communication activity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXNOR0200H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEthernet\/Serial RTU Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eStandard and severe environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003e1 x RJ45, 10\/100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Standards\u003c\/td\u003e\n\u003ctd\u003e10BASE-T \/ 100BASE-TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003ctd\u003e1 x RJ45, RS232\/RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Transmission Rate\u003c\/td\u003e\n\u003ctd\u003e300\/38400 bit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eDNP3, DNP3 IP, IEC 60870-5-101, IEC 60870-5-104, Modbus\/TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Modes\u003c\/td\u003e\n\u003ctd\u003eMulti-protocol master and slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Services\u003c\/td\u003e\n\u003ctd\u003eFTP, SMTP, NTP, SNMP, BootP, DHCP, FDR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvent Management\u003c\/td\u003e\n\u003ctd\u003eTimestamped events and automatic event backup on power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003eCSV file logging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Card\u003c\/td\u003e\n\u003ctd\u003eBMXRWS128MWF SD flash card, 128000 kB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eInternal supply via module rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e95 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Diagnostics\u003c\/td\u003e\n\u003ctd\u003e8 LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10-95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Resistance\u003c\/td\u003e\n\u003ctd\u003eGas, dust, sand, salt and fungal growth resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, RCM, EAC, UKCA, ATEX Zone 2\/22, IECEx Zone 2\/22, Marine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2, IEC 61010-2-201, UL 61010-2-201, CSA C22.2 No. 61010-2-201, IACS E10, IEC 61850-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e3595864105314\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Lifecycle Carbon Footprint\u003c\/td\u003e\n\u003ctd\u003e120 kg CO2 eq.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eRTU Integration with SCADA Systems\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXNOR0200H handles communication between remote control stations and supervisory systems. In an upstream configuration, it can communicate with a SCADA system in server or slave mode. In a downstream configuration, it can operate as a master to communicate with remote field devices.\u003c\/p\u003e\n\u003cp\u003eTimestamped event handling preserves the time information associated with reported changes. Transparent event routing allows events received from remote slave devices to be forwarded to the supervisory system. Automatic event backup on power loss helps retain event information during an interruption of the module's power supply.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower and Environmental Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module receives its operating power internally through the Modicon X80 rack. Its specified current consumption is 95 mA at 24 VDC. This is a rack-supplied current requirement, not a standalone 24 VDC power input.\u003c\/p\u003e\n\u003cp\u003eThe conformal coating and specified environmental resistance characteristics distinguish this version from standard-environment communication hardware. Its IP20 rating still requires installation inside an appropriately protected enclosure; ruggedized environmental characteristics do not indicate a higher ingress protection rating.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePlatform Compatibility and Lifecycle\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXNOR0200H is specified for use with Modicon M340 and Modicon M580 programmable automation controllers. It belongs to the Modicon X80 common I\/O platform, which provides a shared module environment across these controller families.\u003c\/p\u003e\n\u003cp\u003eSchneider Electric lists \u003cstrong\u003e1 December 2027\u003c\/strong\u003e as the sales discontinuation date and \u003cstrong\u003e31 December 2035\u003c\/strong\u003e as the service discontinuation date. The manufacturer also identifies BMENOR2200H as an alternative module to consider. Technical constraints, communication configuration and application requirements should be checked before selecting it as a replacement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which communication protocols does the BMXNOR0200H support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It supports DNP3, DNP3 IP, IEC 60870-5-101, IEC 60870-5-104 and Modbus\/TCP messaging. It also provides timestamped event management and communication services for remote modem connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the BMXNOR0200H communicate through both Ethernet and serial interfaces?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. It has one Ethernet RJ45 interface supporting 10\/100 Mbps and one serial RJ45 interface supporting RS232\/RS485. The serial interface supports communication at the specified 300\/38400 bit\/s rates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the BMXNOR0200H suitable for Modicon M580 applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module is specified for both Modicon M340 and M580 platforms. The rack, processor configuration and applicable hardware and firmware requirements should be checked before installation.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":68137377890589,"sku":"BMXNOR0200H","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXNOR0200H.jpg?v=1795167804","url":"https:\/\/www.6gcontrols.com\/tr\/products\/schneider-electric-bmxnor0200h-modicon-x80-rtu-communication-module","provider":"6G Controls","version":"1.0","type":"link"}