{"product_id":"yokogawa-sai143-h53-prp-analog-input-module-in-stock","title":"Yokogawa SAI143-H53\/PRP Analog Giriş Modülü Stokta","description":"\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003cdiv class=\"textContainer headline headline-cursor\"\u003e\n\u003ch3\u003e\n\u003cstrong\u003eOverview\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa SAI143-H53\/PRP\u003c\/strong\u003e is a high-reliability 16-channel analog input module designed for \u003cstrong\u003eProSafe-RS\u003c\/strong\u003e safety instrumented systems. It supports \u003cstrong\u003e4 to 20 mA\u003c\/strong\u003e signals and integrates \u003cstrong\u003eHART 7\u003c\/strong\u003e communication for advanced device diagnostics. Each channel offers \u003cstrong\u003egalvanic isolation\u003c\/strong\u003e, enhancing system safety and fault tolerance. The module includes a \u003cstrong\u003efalse insertion prevention pin\u003c\/strong\u003e with option code \u003cstrong\u003e\/PRP\u003c\/strong\u003e, ensuring correct installation in critical safety applications. Furthermore, it supports \u003cstrong\u003edual-redundant configurations\u003c\/strong\u003e, minimizing single-point failures and increasing operational uptime.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003ch4\u003e\n\u003cstrong\u003eInput Specifications\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e: 16 isolated input channels\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Input Range\u003c\/strong\u003e: 4 to 20 mA DC\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermissible Input Range\u003c\/strong\u003e: 0 to 25 mA\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±16 µA (input range 0.05 to 23 mA)\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance (Power ON)\u003c\/strong\u003e: 250 Ω + voltage drop (varies with current)\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance (Power OFF)\u003c\/strong\u003e: ≥500 kΩ\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Drop\u003c\/strong\u003e: Max 0.45 V\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Update Frequency\u003c\/strong\u003e: 40 ms\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Drift\u003c\/strong\u003e: ±16 µA \/ 10 °C\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\n\u003cstrong\u003eTransmitter Power Supply\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e: 16.15 V (min, 20 mA) to 26.4 V (max, 0 mA)\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current Limit\u003c\/strong\u003e: 25 mA\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2\/4-Wire Setting\u003c\/strong\u003e: Configurable per channel via setting pins\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower ON\/OFF Function\u003c\/strong\u003e: Available for all channels in 2-wire mode\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\n\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eWithstand Voltage\u003c\/strong\u003e: 1.5 kV AC (between input signal and system for 1 minute)\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Current Consumption\u003c\/strong\u003e:\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n320 mA (5 V system)\n\u003c\/li\u003e\n\u003cli\u003e\n550 mA (24 V system)\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\n\u003cstrong\u003eCommunication\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol\u003c\/strong\u003e: HART 7 supported\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\n\u003cstrong\u003eMechanical \u0026amp; Installation\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.39 kg\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: DIN rail or rack mount\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable\u003c\/strong\u003e: Yes\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Connections\u003c\/strong\u003e:\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\nPressure clamp terminal\n\u003c\/li\u003e\n\u003cli\u003e\nMIL connector cable\n\u003c\/li\u003e\n\u003cli\u003e\nDedicated signal cable (KS1)\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFalse Insertion Prevention\u003c\/strong\u003e: Yes (with \/PRP option)\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\n\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -20°C to +70°C\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating\u003c\/strong\u003e: IP20\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Standard\u003c\/strong\u003e: ISA G3 (harsh environments)\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52756826980637,"sku":"SAI143-H53\/PRP","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/SAI143-H53-PRP_1000.jpg?v=1787201875","url":"https:\/\/www.6gcontrols.com\/tr\/products\/yokogawa-sai143-h53-prp-analog-input-module-in-stock","provider":"6G Controls","version":"1.0","type":"link"}