{"product_id":"ge-ic200alg320e-versamax-analog-output-module","title":"GE IC200ALG320E VersaMax Analog Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC200ALG320E\u003c\/strong\u003e is a 12-bit analog current output module for the VersaMax distributed I\/O system. It provides four single-ended output channels, each delivering a 4-20 mA signal to external control devices. The module uses an external DC supply for its field-side outputs and supports selectable output behavior when normal backplane communication or power is interrupted.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Function and Signal Processing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG320E converts digital output data received from the VersaMax CPU or Network Interface Unit (NIU) into analog current signals. Its four output channels operate as current-sourcing outputs and are arranged in one group.\u003c\/p\u003e\n\u003cp\u003eThe 4-20 mA signal range supports analog control loops connected to devices such as positioners, control valves, and other current-operated equipment. Each channel receives its own output data, allowing the controller to command multiple field devices through one module.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Configuration and Failure Behavior\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides a jumper-selectable response for conditions such as loss of backplane power, interruption of communication, or a stopped controller. The outputs can be configured to return to a default value of \u003cstrong\u003e4 mA\u003c\/strong\u003e or hold their last output state.\u003c\/p\u003e\n\u003cp\u003eThis setting determines how connected equipment responds when normal output updates are unavailable. The configured behavior should therefore be checked before replacing an existing module, particularly where the analog output controls a process actuator.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG320E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVersaMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle-ended, one group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e4 uA = 8 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e0.3 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy at 25 deg C\u003c\/td\u003e\n\u003ctd\u003e+\/-0.3% typical of full scale; +\/-0.5% maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e18-30 VDC, including ripple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Current Consumption\u003c\/td\u003e\n\u003ctd\u003e160 mA maximum, including load current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Consumption\u003c\/td\u003e\n\u003ctd\u003e50 mA maximum at 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Default Configuration\u003c\/td\u003e\n\u003ctd\u003e4 mA or hold last state\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003eFLD PWR, OK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.9 x 6.4 x 5.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eRevision E Identification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe suffix E identifies a revision of the original IC200ALG320 module. Revision E features an improved latching mechanism compared with earlier versions. When sourcing a replacement, check the complete catalog number and mechanical retention arrangement rather than identifying the module only by its base number.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Field Wiring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module requires a VersaMax I\/O carrier and an external 18-30 VDC supply for its output circuits. Shielded twisted-pair cable is recommended for analog field connections to help limit electrical interference in the current signal wiring.\u003c\/p\u003e\n\u003cp\u003eThe FLD PWR LED indicates the presence of field-side power, while the OK LED indicates that backplane power is recognized. These indicators help distinguish a field power issue from a backplane power issue during maintenance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between IC200ALG320E and IC200ALG320?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Both belong to the same four-channel, 12-bit, 4-20 mA analog output module family. The IC200ALG320E is Revision E and features an improved latching mechanism.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens to the outputs if backplane communication is interrupted?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The outputs follow the configured jumper setting. They can return to the 4 mA default value or retain their last output state. Verify the existing configuration before replacing the module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the IC200ALG320E require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Its analog output circuits require an external 18-30 VDC supply. The module also draws current from the 5 V backplane supply, so both power requirements must be considered when checking the installation.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":68095500353821,"sku":"IC200ALG320E","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/IC200ALG320E2.jpg?v=1794819815","url":"https:\/\/www.6gcontrols.com\/vi\/products\/ge-ic200alg320e-versamax-analog-output-module","provider":"6G Controls","version":"1.0","type":"link"}