{"product_id":"schneider-bmxxbp1200h-ruggedized-ethernet-backplane-rack","title":"Schneider BMXXBP1200H Ruggedized Ethernet Backplane Rack","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric BMXXBP1200H\u003c\/strong\u003e is a 12-slot ruggedized Ethernet backplane rack for the Modicon M340 automation platform. It provides the X-bus connections required to mount and electrically connect BMXP34 processors, BMXCPS power supplies, I\/O modules, and application-specific modules. Designed for severe environmental conditions, it supports an operating temperature range of -25 to +70 deg C and uses conformal coating for additional environmental protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBackplane Function and Module Arrangement\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BMXXBP1200H provides \u003cstrong\u003e12 X-bus slots\u003c\/strong\u003e for installing compatible automation modules. The backplane establishes the electrical connections between installed modules, allowing the processor to communicate with I\/O and application-specific modules through the rack architecture.\u003c\/p\u003e\n\u003cp\u003eIt is designed for Modicon M340 processor configurations using BMXP34 processors and BMXCPS power supplies. The XBE expansion connector provides an electrical connection for an expansion module, where supported by the system configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRuggedized Construction and Mounting\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUnlike standard-environment rack configurations, the BMXXBP1200H is designed for applications requiring an extended environmental operating range. Its conformal coating and specified resistance to gases, dust, sand, salt, and fungal growth support installation in more demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003eThe rack is mounted directly onto a panel or mounting plate using four M4, M5, or M6 screws. Its IP20 protection rating indicates that it is intended for installation inside an appropriately protected electrical enclosure rather than direct exposure to water or outdoor weather.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXXBP1200H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRuggedized Ethernet Backplane Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eSevere environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Slots\u003c\/td\u003e\n\u003ctd\u003e12 X-bus slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Processor\u003c\/td\u003e\n\u003ctd\u003eBMXP34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Power Supply\u003c\/td\u003e\n\u003ctd\u003eBMXCPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Compatibility\u003c\/td\u003e\n\u003ctd\u003eI\/O modules, specific application modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003e1 XBE expansion module connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.83 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel or mounting plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixing\u003c\/td\u003e\n\u003ctd\u003e4 M4\/M5\/M6 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e103.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e503.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e19 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10-95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Gas Resistance\u003c\/td\u003e\n\u003ctd\u003eClass Gx, ISA S71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Resistance\u003c\/td\u003e\n\u003ctd\u003eClass 3C4, IEC 60721-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDust Resistance\u003c\/td\u003e\n\u003ctd\u003eClass 3S4, IEC 60721-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSand Resistance\u003c\/td\u003e\n\u003ctd\u003eClass 3S4, IEC 60721-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalt Resistance\u003c\/td\u003e\n\u003ctd\u003eLevel 2, IEC 68252\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMold Growth Resistance\u003c\/td\u003e\n\u003ctd\u003eClass 3B2, IEC 60721-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFungal Spore Resistance\u003c\/td\u003e\n\u003ctd\u003eClass 3B2, IEC 60721-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location Classification\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, RCM, EAC, UKCA, Merchant Navy, ATEX Zone 2\/22, IECEx Zone 2\/22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 61131-2, EN\/IEC 61010-2-201, UL 61010-2-201, CSA C22.2 No 61010-2-201, IACS E10, EN\/IEC 61000-6-5, EN\/IEC 61850-3, EN\/IEC 60079-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Carbon Footprint\u003c\/td\u003e\n\u003ctd\u003e49 kg CO2 eq.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Configuration Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSecure the rack using four M4, M5, or M6 screws on a suitable panel or mounting plate.\u003c\/li\u003e\n\u003cli\u003eConfirm that the selected BMXP34 processor, BMXCPS power supply, and installed I\/O or application modules are supported by the intended rack configuration.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified operating temperature and non-condensing humidity conditions.\u003c\/li\u003e\n\u003cli\u003eFor hazardous-area installations, verify the applicable Zone 2\/22 or Class I, Division 2 requirements for the complete installed assembly. The rack's product certifications alone do not establish certification of the entire control system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many modules can the BMXXBP1200H accommodate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The rack provides 12 X-bus slots. The actual number of installable modules depends on the slot allocation and the requirements of the selected processor, power supply, and application modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which Modicon modules are compatible with the BMXXBP1200H?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified compatible equipment includes BMXP34 processors, BMXCPS power supplies, I\/O modules, and specific application modules. Compatibility should be checked against the individual module references and system configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the BMXXBP1200H and a standard backplane rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The BMXXBP1200H is a ruggedized version designed for severe environments. Its distinguishing characteristics include conformal coating, an extended operating temperature range of -25 to +70 deg C, and specified resistance to gases, dust, sand, salt, and fungal growth.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":68165922914589,"sku":"BMXXBP1200H","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXXBP1200H2.jpg?v=1795507116","url":"https:\/\/www.6gcontrols.com\/vi\/products\/schneider-bmxxbp1200h-ruggedized-ethernet-backplane-rack","provider":"6G Controls","version":"1.0","type":"link"}