{"product_id":"schneider-electric-bmxdao1615-modicon-x80-discrete-output-module","title":"Schneider Electric BMXDAO1615 Modicon X80 Discrete Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eBMXDAO1615\u003c\/strong\u003e is a 16-channel isolated triac discrete output module within the Schneider Electric Modicon X80 I\/O platform, designed for Modicon M340 and M580 automation architectures. Operating across a 24 to 240 VAC load supply range, it switches AC field actuators at up to 3 A per channel at 40 deg C. This standard-coated version features TC all-climate treatment, 3000 VAC dielectric isolation, and an IP20 enclosure rating for backplane rack mounting.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXDAO1615\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 (isolated triac outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current per Channel\u003c\/td\u003e\n\u003ctd\u003e3 A at 40 deg C; 1.2 A at 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per Module\u003c\/td\u003e\n\u003ctd\u003e10 A at \u0026lt;40 deg C; 4 A at \u0026lt;60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Limits\u003c\/td\u003e\n\u003ctd\u003e0.005 to 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 ms (resistive activation and deactivation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1.55 V at state 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Protection\u003c\/td\u003e\n\u003ctd\u003e1 external 4 A fast-blow fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e3000 VAC at 50\/60 Hz for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm at 500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003ctd\u003eStandard version (TC all-climate treatment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 % at 0 to 60 deg C (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e496,732 hours (500,000 hours nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.264 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN Code\u003c\/td\u003e\n\u003ctd\u003e3606489485047\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards \u0026amp; Certifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, RCM, EAC, UKCA, Merchant Marine; EN 61000-6-5, EN 61850-3, EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eLoad Derating and Protection Requirements\u003c\/h3\u003e\n\u003cp\u003eCurrent capacity on the \u003cstrong\u003eBMXDAO1615\u003c\/strong\u003e scales directly with ambient enclosure temperature. While a single channel handles up to 3 A at 40 deg C, total module current is capped at 10 A below 40 deg C. At the upper operating limit of 60 deg C, channel capacity derates to 1.2 A and total module output drops to 4 A.\u003c\/p\u003e\n\u003cp\u003eThe triac switching stage handles inrush surges up to 30 A and requires a minimum load current of 0.005 A to maintain latch-on conduction. Because the module lacks internal per-channel electronic short-circuit tripping, circuit protection relies on an external 4 A fast-blow fuse.\u003c\/p\u003e\n\u003ch3\u003eSystem Compatibility and Wiring\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBMXDAO1615\u003c\/strong\u003e integrates into Modicon M340 local racks as well as Modicon M580 local and remote I\/O drops. Field wiring connects through a removable 40-pin cage-clamp or spring-clamp terminal block (ordered separately as an accessory). During installation, seat the module into the Modicon X80 backplane rack and secure it using two mounting screws.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What terminal block is required to wire the BMXDAO1615?A: The module uses a removable 40-pin terminal block available in either cage-clamp or spring-clamp styles, which is supplied as a separate Modicon X80 accessory.\u003c\/p\u003e\n\u003cp\u003eQ: How does the BMXDAO1615 differ from the conformal-coated variant in the same product family?A: The BMXDAO1615 is the standard non-conformal-coated version (with TC all-climate treatment) rated for 0 to 60 deg C, whereas the conformal-coated option (typically suffixed with H in Modicon X80) is designed for extended harsh environments.\u003c\/p\u003e\n\u003cp\u003eQ: Does the BMXDAO1615 include built-in short-circuit protection for its triac outputs?A: No, external circuit protection is required using a 4 A fast-blow fuse to protect the triac outputs against overloads and short circuits.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":68109359317277,"sku":"BMXDAO1615","price":9.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0983\/5387\/3181\/files\/BMXDAO16152.jpg?v=1794906028","url":"https:\/\/www.6gcontrols.com\/vi\/products\/schneider-electric-bmxdao1615-modicon-x80-discrete-output-module","provider":"6G Controls","version":"1.0","type":"link"}