The Honeywell 10302/2/1 12600, also cataloged as the 10302/2/1 Watchdog Repeater Module, monitors the 5 VDC and 24 VDC supply voltages for I/O modules in Honeywell safety control systems. It provides a watchdog output to monitored output modules and supports power supply monitoring in multiple-PSU configurations, mixed redundant and non-redundant I/O arrangements, and systems requiring additional watchdog current capacity.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 10302/2/1 |
| Type Number | 10302/2/1 12600 |
| Product Type | Watchdog Repeater Module (WDR) |
| Brand | Honeywell |
| Weight | 0.12 kg |
| Dimensions | 4 TE x 3 HE (4 HP x 3U rack space) |
| 5 VDC Supply Current | 35 mA, excluding WDROUT output current |
| 24 VDC Supply Current | 25 mA |
| WDG1 + WDG2 Input Current | 0.1 mA |
| Monitored Supply Voltages | 5 VDC and 24 VDC |
| Required Watchdog Current | Repeater required when current exceeds 900 mA |
| 24 VDC Supply Voltage Condition | Supply output must remain below 37 VDC under any single or double fault condition |
| Software Version | Version 3.00 or later |
| Approvals | CE, TÜV, UL |
| Backplane Connector | Male DIN 41612, Type F |
| Connector Rows | d, b, z |
| Module Key Coding | Holes A5, A9 |
| Rack Key Coding | Large pins A5, A9 |
| Horizontal Bus Connection | Required |
Watchdog Output and Power Supply Monitoring
The 10302/2/1 monitors the designated I/O power supply voltages and connects its watchdog output to the watchdog inputs of the corresponding output modules. Installation is required in specific configurations:
- Multiple power supply units: One repeater is required for each subsequent 24 VDC to 5 VDC power supply unit, such as PSU 2, PSU 3, or PSU 4.
- Specified power supplies: Required when 24 VDC is supplied through an M24-20 HE or M24-12 HE power supply.
- Elevated supply voltage: Required when the 24 VDC source can exceed 31.0 VDC. The supply output must remain below 37 VDC under single- or double-fault conditions.
- High watchdog current: Required when the watchdog current demand exceeds 900 mA.
- Mixed I/O redundancy: Generates the watchdog output for non-redundant output modules in configurations combining redundant and non-redundant I/O.
- Redundant Central Parts: Supports 5 VDC monitoring in configurations with redundant Central Parts and non-redundant I/O when 5 VDC monitoring is otherwise absent.
The module requires a horizontal bus connection. Rack space must be reserved at positions 1, 2, or 11-18 as applicable to the rack configuration. Each repeater must be installed in the same I/O section as the output modules it monitors.
Frequently Asked Questions (FAQ)
Q: Can the 10302/2/1 be replaced while the power supply is energized?
A: Yes. The module can be exchanged with the power supply switched on. However, the Central Part will shut down during the exchange. In configurations with redundant Central Parts and non-redundant I/O, both Central Parts will shut down.
Q: Which connector and rack positions does the module require?
A: It uses a male DIN 41612 Type F connector with the d, b, and z rows. It requires a horizontal bus connection and occupies 4 TE x 3 HE (4 HP x 3U). Rack positions must be allocated according to the applicable I/O rack configuration.
Q: What are the module's power supply requirements?
A: The module draws 35 mA from the 5 VDC supply, excluding WDROUT output current, and 25 mA from the 24 VDC supply. The combined WDG1 and WDG2 input current is 0.1 mA.
Field Installation Guidelines
- Verify rack compatibility and reserve the required 4 HP x 3U mounting space before installation.
- Confirm that the horizontal bus connection is available at the intended rack position.
- Check module and rack key coding. The module uses holes A5 and A9, while the rack uses large pins at A5 and A9.
- Install the repeater in the I/O section containing the output modules it monitors. Do not use a repeater installed in one I/O section to control another section.
- Verify the 5 VDC and 24 VDC supply conditions and account for WDROUT output current when calculating the total 5 VDC load.
- For 24 VDC supplies that may exceed 31.0 VDC, verify that the maximum output remains below 37 VDC under single- or double-fault conditions.
- Follow the system manufacturer's approved replacement procedure. Energized replacement can cause the Central Part or both Central Parts to shut down, depending on system configuration.
- Verify connector alignment and engage the backplane connector without applying excessive mechanical force.
پرداخت: حواله بانکی، وسترن یونیون.
بندر حمل: شیامن.
زمان آمادهسازی: معمولاً ۱ تا ۳ روز کاری پس از تأیید پرداخت (مشروط به موجودی).
تحویل در سراسر جهان: قطعات اتوماسیون صنعتی را برای مشتریان سراسر جهان ارسال میکنیم. هزینه حمل با درخواست استعلام قیمت شما اعلام میشود.
پرسشهای متداول
پرسشهای متداول درباره قیمتها، ارسال، گارانتی و مرجوعیدر صفحهٔ محصول روی درخواست قیمت کلیک کنید و شمارهٔ قطعه، مقدار موردنیاز و کشور مقصد را برای ما ارسال کنید. تیم فروش ما دربارهٔ موجودی فعلی، قیمت و زمان تقریبی تحویل پاسخ خواهد داد.
اقلام موجود معمولاً پس از پرداخت و تأیید سفارش آماده میشوند. بیشتر سفارشها از انبار ما در چین ارسال میشوند، هرچند محل ارسال ممکن است بسته به موجودی فعلی متفاوت باشد.
بله. قطعات اتوماسیون صنعتی را برای مشتریان سراسر جهان ارسال میکنیم. هزینه ارسال و زمان حملونقل به مقصد، وزن بسته، اندازه محصول و الزامات واردات محلی بستگی دارد.
ما معمولاً از خدمات پیک بینالمللی DHL، FedEx، UPS و سایر شرکتها استفاده میکنیم. شرکت حملونقل را میتوان بر اساس مقصد، سرعت تحویل، اندازه محموله و نیازهای مشتری انتخاب کرد.
محصولات ما معمولاً شامل ضمانت ۱۲ماهه هستند. محصولات واجد شرایط همچنین ممکن است طبق سیاست بازپرداخت ۳۰روزه قابل بازگشت باشند. لطفاً پیش از بازگرداندن هر کالا با تیم ما تماس بگیرید تا شرایط قابلاعمال و دستورالعملهای بازگشت را تأیید کنید.
ممکن است اینها را هم بپسندید
پستهای وبلاگ
اخبار اتوماسیون صنعتی، راهنماهای فنی و بهروزرسانیهای محصولات.