وقتی این محصول در دسترس قرار گرفت، از طریق ایمیل اطلاعرسانی شود
- توضیحات
- Reviews
- ارسال و پرداخت
Schneider Electric ATV71HC40N4 Altivar 71 Variable Speed Drive
Configured for high-power motor speed control in Altivar 71 drive platforms, the Schneider Electric ATV71HC40N4 (ATV71 variable speed drive) provides direct physical/electrical execution for three-phase motor regulation, power conversion, and control signal processing. The drive handles 380...480 V AC input, 400 kW / 600 hp motor applications, and integrates EMC filtering, Modbus/CANopen communication, and configurable analog/digital I/O interfaces.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | ATV71HC40N4 |
| Brand | Schneider Electric |
| Origin | France |
| Weight | 330 kg |
| Dimensions | 890 mm (W) x 377 mm (D) x 1390 mm (H) |
| Operating Temp | -10...50 deg C without derating |
| Power Consumption | 466.6 kVA apparent power at 380 V, 400 kW application |
| Product Type | Variable Speed Drive |
| Series | Altivar 71 |
| Motor Power | 400 kW / 600 hp, 3 phases, 380...480 V AC |
| Supply Voltage | 380...480 V AC -15...10 % |
| Network Phases | 3 phases |
| Integrated EMC Filter | Yes |
| Nominal Output Current | 759 A at 2.5 kHz, 400 kW application |
| Maximum Transient Current | 1252 A for 2 s |
| Output Frequency | 0.1...500 Hz |
| Adjustable Switching Frequency | 2.5...8 kHz |
| Communication Protocols | Modbus RTU, CANopen |
| Analog Inputs | 2 channels |
| Analog Output | 1 channel |
| Digital Inputs | 7 channels |
| Digital Outputs | 2 relay outputs |
| Protection Rating | IP20 |
| Installation Position | Vertical +/- 10 deg |
Profinet / EtherNet-IP Deterministic Network and Drive Control Architecture
The Altivar 71 platform supports deterministic industrial communication through optional network interface cards, including EtherNet/IP, Modbus TCP, Profibus DP, DeviceNet, and CANopen extensions. The ATV71HC40N4 processes motor commands, feedback signals, and parameter data through internal control logic with configurable communication access.
The drive supports flux vector control with encoder feedback, sensorless flux vector control, and voltage/frequency control profiles. Speed accuracy reaches +/- 0.01 % of nominal speed in closed-loop operation with encoder feedback, while torque regulation supports closed-loop accuracy of +/- 5 %.
I/O Density Scaling and Control Signal Processing
The ATV71HC40N4 provides configurable analog and digital interfaces for machine control integration. Analog input channels support bipolar voltage, current, and voltage references, while relay outputs provide configurable switching functions.
Signal characteristics include:
- AI1 differential voltage input: +/- 10 V DC, 11 bits + sign resolution
- AI2 configurable current input: 0...20 mA
- AI2 configurable voltage input: 0...10 V DC
- AO1 configurable output: 0...20 mA or 0...10 V DC
- Digital inputs: 24 V DC programmable logic
- Safety input: PWR 24 V DC conforming to ISO 13849-1 level d
Frequently Asked Questions (FAQ)
Q: Does the ATV71HC40N4 support encoder feedback for closed-loop speed control? A: Yes. The drive supports closed-loop asynchronous motor control using encoder feedback through an optional encoder interface card.
Q: What communication interfaces are available on the ATV71HC40N4? A: The standard communication interfaces include Modbus RTU and CANopen. Optional communication cards support additional industrial protocols.
Q: What are the motor cable length limitations? A: The maximum motor cable length is 100 m with shielded cable and 200 m with unshielded cable under specified installation conditions.
Field Installation Guidelines
Install the drive vertically with sufficient clearance for heat sink ventilation and service access. Use cable routing practices that separate power conductors from control and communication wiring to reduce electromagnetic interference.
Connect motor cables using shielded cable where EMC performance is required. Terminate cable shields according to industrial EMC grounding practices, with low-impedance connections to the drive enclosure or grounding points.
Verify terminal tightening torque according to the manufacturer installation documentation. Inspect power terminals, DC bus connections, and control wiring before energizing the unit.
For communication networks, use suitable RS 485 wiring practices for Modbus connections, including correct polarity, termination, and cable shielding. Avoid routing communication cables parallel to high-current motor conductors.
پرداخت: حواله بانکی، وسترن یونیون.
بندر حمل: شیامن.
زمان آمادهسازی: معمولاً ۱ تا ۳ روز کاری پس از تأیید پرداخت (مشروط به موجودی).
تحویل در سراسر جهان: قطعات اتوماسیون صنعتی را برای مشتریان سراسر جهان ارسال میکنیم. هزینه حمل با درخواست استعلام قیمت شما اعلام میشود.
پرسشهای متداول
پرسشهای متداول درباره قیمتها، ارسال، گارانتی و مرجوعیدر صفحهٔ محصول روی درخواست قیمت کلیک کنید و شمارهٔ قطعه، مقدار موردنیاز و کشور مقصد را برای ما ارسال کنید. تیم فروش ما دربارهٔ موجودی فعلی، قیمت و زمان تقریبی تحویل پاسخ خواهد داد.
اقلام موجود معمولاً پس از پرداخت و تأیید سفارش آماده میشوند. بیشتر سفارشها از انبار ما در چین ارسال میشوند، هرچند محل ارسال ممکن است بسته به موجودی فعلی متفاوت باشد.
بله. قطعات اتوماسیون صنعتی را برای مشتریان سراسر جهان ارسال میکنیم. هزینه ارسال و زمان حملونقل به مقصد، وزن بسته، اندازه محصول و الزامات واردات محلی بستگی دارد.
ما معمولاً از خدمات پیک بینالمللی DHL، FedEx، UPS و سایر شرکتها استفاده میکنیم. شرکت حملونقل را میتوان بر اساس مقصد، سرعت تحویل، اندازه محموله و نیازهای مشتری انتخاب کرد.
محصولات ما معمولاً شامل ضمانت ۱۲ماهه هستند. محصولات واجد شرایط همچنین ممکن است طبق سیاست بازپرداخت ۳۰روزه قابل بازگشت باشند. لطفاً پیش از بازگرداندن هر کالا با تیم ما تماس بگیرید تا شرایط قابلاعمال و دستورالعملهای بازگشت را تأیید کنید.
ممکن است اینها را هم بپسندید
پستهای وبلاگ
اخبار اتوماسیون صنعتی، راهنماهای فنی و بهروزرسانیهای محصولات.