وقتی این محصول در دسترس قرار گرفت، از طریق ایمیل اطلاعرسانی شود
- توضیحات
- Reviews
- ارسال و پرداخت
Configured for isolated low-level analog signal acquisition in the Modicon X80 platform, the Schneider Electric BMXART0414 (BMXART0414 Analog Input Module) provides four isolated input channels with configurable voltage, resistance, temperature probe, and thermocouple measurement functions. The module uses a 40-way connector and occupies one rack slot.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | BMXART0414 |
| Brand | Schneider Electric |
| Product Type | Analog isolated low level input module |
| Series | Modicon X80 |
| Origin | US |
| Number of Inputs | 4 |
| Input Level | Low level |
| Input Isolation | Isolated |
| Electrical Connection | 40-way, 1 connector |
| Analog Input Type | Voltage, resistance, temperature probe, thermocouple |
| Voltage Ranges | +/- 40 mV, +/- 80 mV, +/- 160 mV, +/- 320 mV, +/- 640 mV, +/- 1.28 V |
| Resistance Inputs | 400 Ohm and 4000 Ohm, 2-wire, 3-wire, or 4-wire |
| Analog/Digital Conversion | Sigma delta, 16 bits |
| Analog Input Resolution | 15 bits + sign |
| Common Mode Rejection | 120 dB at 50/60 Hz |
| Differential Mode Rejection | 60 dB at 50/60 Hz |
| Cold Junction Compensation | External by Pt100 probe |
| Digital Filtering | First order digital filtering |
| Nominal Read Cycle | 400 ms with temperature probe; 200 ms with thermocouple |
| Isolation Voltage | 1400 V DC between channels and bus; 750 V DC between channels; 750 V DC between channels and ground |
| Maximum Wiring Resistance | Up to 500 Ohm depending on sensor type and wiring configuration |
| Measurement Resolution | 0.1 deg C for supported temperature probe and thermocouple configurations |
| Recalibration | Internal |
| Status Indication | RUN, channel diagnostic, ERR, and I/O LEDs |
| Weight | 0.135 kg |
| Operating Temp | 0 to 60 deg C |
| Storage Temp | -40 to 85 deg C |
| Relative Humidity | 5 to 95% at 55 deg C, non-condensing |
| IP Rating | IP20 |
| Vibration Resistance | 3 gn |
| Shock Resistance | 30 gn |
| Power Consumption | 150 mA at 3.3 VDC; 40 mA at 24 VDC |
| Latest Firmware | SV2.3 |
| Certifications | EAC, RCM, UL, Merchant Navy, CSA, CE |
| Standards | IEC 61131-2, IEC 61000-6-4, IEC 61000-6-2, EN 61010-2-201 |
Industrial Control and I/O Characteristics
The BMXART0414 provides four independently isolated analog acquisition channels within one Modicon X80 rack slot. Its low-level ranges extend from +/- 40 mV to +/- 1.28 V, while resistance and temperature configurations support multiple 2-wire, 3-wire, and 4-wire sensor arrangements. The module performs 16-bit sigma-delta conversion with a stated analog resolution of 15 bits plus sign.
Channel and bus isolation are specified at 1400 V DC, while channel-to-channel and channel-to-ground isolation are specified at 750 V DC. Common-mode rejection is 120 dB at 50/60 Hz and differential-mode rejection is 60 dB at 50/60 Hz.
The module supports internal recalibration and first-order digital filtering. Temperature and thermocouple configurations use external Pt100-based cold junction compensation where specified. The source lists SV2.3 as the latest firmware version for the product.
Frequently Asked Questions
Q: How many analog channels does the BMXART0414 provide?
A: The module provides four isolated low-level analog input channels.
Q: What signal types can be connected to the BMXART0414?
A: Depending on configuration, the inputs support low-level voltage, 400 Ohm and 4000 Ohm resistance, temperature probes, and thermocouples.
Q: What is the specified module power consumption?
A: The source specifies 150 mA at 3.3 VDC and 40 mA at 24 VDC.
Field Installation Guidelines
Install the BMXART0414 in its designated Modicon X80 rack slot and connect the field wiring through the specified 40-way connector. Confirm the configured input type before wiring each channel because voltage, resistance, temperature probe, and thermocouple configurations use different electrical measurement arrangements.
For low-level analog signals, route sensor wiring separately from high-current power conductors and switching circuits. Maintain appropriate shielding and grounding practices for the installation environment. Use the specified wiring configuration for 2-wire, 3-wire, or 4-wire resistance and temperature sensors.
Verify the selected input range against the connected sensor before commissioning. For thermocouple and temperature measurements, confirm the external Pt100 cold junction compensation arrangement where applicable. Check RUN, channel diagnostic, ERR, and I/O status indicators during startup. The module has IP20 protection and an operating temperature range of 0 to 60 deg C.
پرداخت: حواله بانکی، وسترن یونیون.
بندر حمل: شیامن.
زمان آمادهسازی: معمولاً ۱ تا ۳ روز کاری پس از تأیید پرداخت (مشروط به موجودی).
تحویل در سراسر جهان: قطعات اتوماسیون صنعتی را برای مشتریان سراسر جهان ارسال میکنیم. هزینه حمل با درخواست استعلام قیمت شما اعلام میشود.
پرسشهای متداول
پرسشهای متداول درباره قیمتها، ارسال، گارانتی و مرجوعیدر صفحهٔ محصول روی درخواست قیمت کلیک کنید و شمارهٔ قطعه، مقدار موردنیاز و کشور مقصد را برای ما ارسال کنید. تیم فروش ما دربارهٔ موجودی فعلی، قیمت و زمان تقریبی تحویل پاسخ خواهد داد.
اقلام موجود معمولاً پس از پرداخت و تأیید سفارش آماده میشوند. بیشتر سفارشها از انبار ما در چین ارسال میشوند، هرچند محل ارسال ممکن است بسته به موجودی فعلی متفاوت باشد.
بله. قطعات اتوماسیون صنعتی را برای مشتریان سراسر جهان ارسال میکنیم. هزینه ارسال و زمان حملونقل به مقصد، وزن بسته، اندازه محصول و الزامات واردات محلی بستگی دارد.
ما معمولاً از خدمات پیک بینالمللی DHL، FedEx، UPS و سایر شرکتها استفاده میکنیم. شرکت حملونقل را میتوان بر اساس مقصد، سرعت تحویل، اندازه محموله و نیازهای مشتری انتخاب کرد.
محصولات ما معمولاً شامل ضمانت ۱۲ماهه هستند. محصولات واجد شرایط همچنین ممکن است طبق سیاست بازپرداخت ۳۰روزه قابل بازگشت باشند. لطفاً پیش از بازگرداندن هر کالا با تیم ما تماس بگیرید تا شرایط قابلاعمال و دستورالعملهای بازگشت را تأیید کنید.
ممکن است اینها را هم بپسندید