The BMXDAO1605 is a 16-channel AC triac discrete output module in the Schneider Electric Modicon X80 range. It switches AC loads through solid-state outputs, with a rated operating voltage range of 100 to 240 V AC. The module provides individual channel switching, resistive-load response specifications, and external fast-blow fuse protection.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | BMXDAO1605 |
| Brand | Schneider Electric |
| Product Range | Modicon X80 |
| Product Type | Discrete Output Module |
| Number of Outputs | 16 |
| Output Technology | Triac |
| Rated Output Voltage | 100 to 240 V AC |
| Output Voltage Range | 85 to 288 V AC |
| Current per Channel | 0.6 A |
| Output Current Limits | 0.025 to 4.8 A |
| Inrush Current | 20 A |
| Typical Current Consumption | 100 mA at 3.3 V DC |
| Output Response Time | 10 MOhm at 500 V DC |
| Dielectric Strength | 2830 V AC, 50/60 Hz, 1 min |
| Protection | 1 external fast-blow fuse |
| Protection Rating | IP20 |
| Protective Treatment | Standard version |
| MTBF | 1,800,000 h |
| Relative Humidity | 5 to 95% at 55 deg C, non-condensing |
| Package Weight | 203 g |
| GTIN | 3595863966954 |
Output Operation and Protection
The BMXDAO1605 uses triac switching devices to control AC loads. Unlike electromechanical relay outputs, triac outputs have no mechanical contacts. Their solid-state switching characteristics make the module suitable for AC discrete control circuits where the load current and voltage remain within the specified operating limits.
The specified output response time of 1.011 ms applies to resistive-load activation and deactivation. Actual switching behavior with inductive or other non-resistive loads may differ and should be checked against the applicable load requirements.
Electrical Protection and Isolation
The module specifies one external fast-blow fuse as its output protection arrangement. Fuse selection and installation must account for the connected load and the applicable channel current limits. The 20 A inrush current specification should also be considered when evaluating loads with high starting currents.
The insulation resistance and dielectric strength ratings describe electrical isolation performance under the stated test conditions. They should not be interpreted as permission to exceed the rated operating voltage.
Modicon X80 Platform
The BMXDAO1605 belongs to the Modicon X80 common module platform, which is used with Modicon M340 and M580 Programmable Automation Controllers. Its platform classification identifies the product family; the actual rack configuration and controller compatibility should be checked against the relevant hardware configuration documentation.
Operating Conditions and Load Distribution
The output current must be assessed at both channel and group level. The module's total permissible load depends on the number of energized channels and ambient temperature; the individual channel rating should not be treated as an allowance to operate all 16 outputs simultaneously at maximum current.
For a 220 V AC resistive-load example, Schneider Electric's X80 module documentation specifies the following load conditions:
- At 0 to 40 deg C, 16 channels at 0.3 A each correspond to a total load of 4.8 A.
- Above 40 deg C, output loading must follow the specified temperature derating curve.
- At 60 deg C, the maximum total current is reduced to approximately 2.9 A, corresponding to 10 channels at 0.3 A or 16 channels at approximately 0.18 A.
These limits are important when distributing loads across the output groups and checking cabinet operating temperature.
Frequently Asked Questions
Q: What type of loads can the BMXDAO1605 switch?
A: It uses triac outputs for AC switching within the specified 100 to 240 V AC operating range. It is not a DC transistor output module.
Q: Does each output support 0.6 A continuously?
A: The 0.6 A figure is listed in Schneider Electric's product information, but it should not be interpreted as 0.6 A simultaneously on all 16 channels. Total current and channel loading are subject to group limits and temperature derating.
Q: What external protection is required?
A: The module specifies external fast-blow fuse protection. Schneider's connection documentation identifies a 3 A fast-blow fuse for each four-channel group; confirm the applicable wiring diagram and load requirements before installation.
پرداخت: حواله بانکی، وسترن یونیون.
بندر حمل: شیامن.
زمان آمادهسازی: معمولاً ۱ تا ۳ روز کاری پس از تأیید پرداخت (مشروط به موجودی).
تحویل در سراسر جهان: قطعات اتوماسیون صنعتی را برای مشتریان سراسر جهان ارسال میکنیم. هزینه حمل با درخواست استعلام قیمت شما اعلام میشود.
پرسشهای متداول
پرسشهای متداول درباره قیمتها، ارسال، گارانتی و مرجوعیدر صفحهٔ محصول روی درخواست قیمت کلیک کنید و شمارهٔ قطعه، مقدار موردنیاز و کشور مقصد را برای ما ارسال کنید. تیم فروش ما دربارهٔ موجودی فعلی، قیمت و زمان تقریبی تحویل پاسخ خواهد داد.
اقلام موجود معمولاً پس از پرداخت و تأیید سفارش آماده میشوند. بیشتر سفارشها از انبار ما در چین ارسال میشوند، هرچند محل ارسال ممکن است بسته به موجودی فعلی متفاوت باشد.
بله. قطعات اتوماسیون صنعتی را برای مشتریان سراسر جهان ارسال میکنیم. هزینه ارسال و زمان حملونقل به مقصد، وزن بسته، اندازه محصول و الزامات واردات محلی بستگی دارد.
ما معمولاً از خدمات پیک بینالمللی DHL، FedEx، UPS و سایر شرکتها استفاده میکنیم. شرکت حملونقل را میتوان بر اساس مقصد، سرعت تحویل، اندازه محموله و نیازهای مشتری انتخاب کرد.
محصولات ما معمولاً شامل ضمانت ۱۲ماهه هستند. محصولات واجد شرایط همچنین ممکن است طبق سیاست بازپرداخت ۳۰روزه قابل بازگشت باشند. لطفاً پیش از بازگرداندن هر کالا با تیم ما تماس بگیرید تا شرایط قابلاعمال و دستورالعملهای بازگشت را تأیید کنید.
ممکن است اینها را هم بپسندید
پستهای وبلاگ
اخبار اتوماسیون صنعتی، راهنماهای فنی و بهروزرسانیهای محصولات.