
Notification par e-mail lorsque ce produit sera disponible
- Description
- Reviews
- Livraison et paiement
Configured for high-speed analog signal acquisition in the Modicon X80 platform, the Schneider Electric BMXAMI0810H (BMXAMI0810H analog input module) provides eight isolated current or voltage inputs with 15 bits plus sign resolution, configurable digital filtering, and a fast read cycle for Modicon M580 and M340 PAC systems.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | BMXAMI0810H |
| Brand | Schneider Electric |
| Series | Modicon X80 |
| Product Type | Isolated analog input module |
| Application | Severe environments |
| Analog Inputs | 8 |
| Input Type | +/- 20 mA, 0-20 mA, 4-20 mA, +/- 10 V, +/- 5 V, 0-10 V, 0-5 V, 1-5 V |
| Input Level | High level |
| Input Isolation | 300 V DC between channels; 1400 V DC between channels and ground; 1400 V DC between channels and bus |
| A/D Conversion | 16 bits |
| Input Resolution | 15 bits + sign |
| Measurement Resolution | 0.36 mV for voltage ranges; 1.4 uA for current ranges |
| Input Impedance | 10 MOhm in voltage mode; 250 Ohm + 3.6-50 Ohm protective resistor in current mode |
| Fast Read Cycle | 1 ms + 1 ms x number of channels used |
| Nominal Read Cycle | 9 ms for 8 channels |
| Digital Filter | First order digital filtering |
| Crosstalk Attenuation | Minimum 80 dB |
| Common Mode Rejection | 80 dB |
| Isolation Voltage | 300 V DC between channels; 1400 V DC between channels and ground and bus |
| Power Consumption | 1.06 W typical / 1.50 W maximum at 24 V DC |
| Current Consumption | 54 mA at 24 V DC; 150 mA at 3.3 V DC |
| Weight | 0.175 kg |
| Dimensions | Package: 5.5 x 11.0 x 11.6 cm; module dimensions not specified in supplied data |
| Operating Temp | -25 to 70 deg C |
| Storage Temp | -40 to 85 deg C |
| Protection Rating | IP20 |
| Electrical Connection | 28-way, 1 connector |
| Protective Treatment | Conformal coating |
| Humidity | 5-95% at 55 deg C, non-condensing |
| Vibration Resistance | 3 gn |
| Shock Resistance | 30 gn |
| Operating Altitude | 0-2000 m; 2000-5000 m with derating |
| Certifications | CE, RCM, CSA, EAC, Merchant Navy, UL, ATEX, IEC-Ex |
| Standards | IEC 61010-2-201, IEC 61131-2, UL 61010-2-201, CSA C22.2 No 61010-2-201 |
Channel Isolation and Analog Signal Processing
The BMXAMI0810H provides eight isolated analog channels for current and voltage measurement. Supported current ranges include +/- 20 mA, 0-20 mA, and 4-20 mA. Voltage ranges include +/- 10 V, +/- 5 V, 0-10 V, 0-5 V, and 1-5 V.
Channel isolation is specified at 300 V DC between channels and 1400 V DC between channels and both ground and the bus. The module provides a minimum 80 dB crosstalk attenuation and 80 dB common mode rejection. These characteristics define the electrical separation and signal rejection available between independently wired analog channels.
The module uses first-order digital filtering. The fast read cycle is 1 ms plus 1 ms for each channel used, while the nominal read cycle is 9 ms with all eight channels active.
Frequently Asked Questions
Q: What analog signal ranges can the BMXAMI0810H accept?
A: The module accepts +/- 20 mA, 0-20 mA, 4-20 mA, +/- 10 V, +/- 5 V, 0-10 V, 0-5 V, and 1-5 V input ranges.
Q: What isolation levels are specified for the analog channels?
A: The specification states 300 V DC isolation between channels and 1400 V DC isolation between channels and ground and between channels and the bus.
Q: What is the power consumption of the module?
A: At 24 V DC, power consumption is 1.06 W typical and 1.50 W maximum. Current consumption is 54 mA at 24 V DC.
Field Installation Guidelines
Install the BMXAMI0810H on the applicable Modicon X80 rack and connect the 28-way field connector according to the module wiring documentation.
Route analog signal wiring separately from high-voltage power conductors, motor cables, and high-current switching circuits where practical. Maintain the specified channel isolation when connecting signals from electrically independent field devices.
Use shielded instrumentation cable where required by the installation environment. Terminate cable shields according to the control cabinet grounding scheme and avoid creating unintended ground loops.
Verify the selected input range against the actual field transmitter or voltage source before commissioning. For 4-20 mA circuits, confirm loop polarity and current range configuration. For voltage inputs, verify signal reference and common wiring before energizing the channel.
The BMXAMI0810H has conformal coating and an operating range of -25 to 70 deg C. Installation should nevertheless maintain the environmental conditions specified for the complete Modicon X80 assembly.
Paiement : virement bancaire, Western Union.
Port d’expédition : Xiamen.
Délai : généralement 1 à 3 jours ouvrés après confirmation du paiement (sous réserve des stocks).
Livraison dans le monde entier : nous expédions des pièces d’automatisation industrielle à des clients du monde entier. Les frais de transport sont indiqués avec votre demande de devis.
Foire aux questions (FAQ)
Questions fréquentes sur les devis, l’expédition, la garantie et les retoursCliquez sur Demander un devis sur la page du produit et envoyez-nous la référence, la quantité souhaitée et le pays de destination. Notre équipe commerciale vous répondra avec les disponibilités actuelles, le prix et le délai de livraison estimé.
Les articles en stock sont généralement préparés après le paiement et la confirmation de la commande. La plupart des commandes sont expédiées depuis notre entrepôt en Chine, bien que le lieu d’expédition puisse varier en fonction des stocks disponibles.
Oui. Nous expédions des pièces d’automatisation industrielle à des clients partout dans le monde. Les frais d’expédition et le délai de transport dépendent de la destination, du poids du colis, de la taille du produit et des exigences locales en matière d’importation.
Nous utilisons généralement DHL, FedEx, UPS et d’autres services de messagerie internationaux. Le transporteur peut être choisi en fonction de la destination, de la rapidité de livraison, de la taille de l’envoi et des exigences du client.
Nos produits sont généralement couverts par une garantie de 12 mois. Les produits admissibles peuvent également être retournés conformément à notre politique de remboursement sous 30 jours. Veuillez contacter notre équipe avant de retourner tout article afin de confirmer les conditions applicables et les instructions de retour.
Vous aimerez peut-être aussi
Articles de blog
Actualités sur l’automatisation industrielle, guides techniques et mises à jour des produits.
