General Information:
- Application: Used to build a complete API 670 machinery protection monitor in conjunction with other AMS 6500 monitors. Suitable for steam, gas, compressors, and hydro turbine machinery.
- Module Type: 1-slot plug-in module, reducing cabinet space requirements compared to traditional four-channel 6U size cards.
- API 670 Compliant: Meets API 670 standards for machinery protection.
- Hot Swappable: Module can be replaced without shutting down the system.
Transducer Inputs:
- Number of Inputs: Two independent or combined monitoring modes.
- Type of Inputs: Eddy current, seismic, or piezoelectric, in differential mode.
- Emerson Sensor Inputs: Channel 1 part numbers: 6422, 6423, 6424, 6425; Channel 2 part number: 6125.
- Isolation: Galvanically separated from power supply.
Channel 1 Displacement Sensor:
- Input Resistance: >100 kΩ
- Input Voltage Range: -1 to -23 VDC
- Input Frequency Range: Adjustable with lower cutoff at 1 or 5 Hz and upper cutoff between 50 - 2000 Hz.
- Smallest Range: 0 - 400 mV peak to peak
- Largest Range: 0 - 2000 mV peak to peak
- Sensor Power Supply: -26.7 VDC, nominal 20 mA (maximum 35 mA)
Channel 2 Case Vibration Sensor:
- Input Resistance: >100 kΩ
- Input Voltage Range: -5 to +15 VDC
- Signal Input Voltage Range: 311 - 9500 mV peak to peak
- Input Frequency Range: Adjustable with lower cutoff at 5 or 10 Hz and upper cutoff between 50 - 1000 or 1600 Hz.
- Sensor Supply for Accelerometer: Constant current, 0 - 8 mA, 30 VDC
Front Panel Outputs:
- Green LED's: Indicate channel OK separately for each channel.
- Red LED's: Indicate alert and danger separately for each channel.
- Front Panel Buffered Outputs: Two outputs for each channel.
Analysis:
- Measurement Modes: Hot configurable, zero to peak, peak to peak, independent dual-channel, or combined dual-channel modes.
- Configurable Parameters: Measuring range, RMS, zero to peak, or peak to peak sensitivity, alert, and danger thresholds, filter frequency ranges.
- Analysis Parameters: Includes ½x, 1 - 10x, and phase angle, available via ModBus TCP/IP output.
Rear Outputs Available:
- Current Mode Outputs: 0/4-20 mA output for each channel, proportional to the main value.
- Voltage Mode Outputs: 0 - 10 VDC output proportional to the main value for each channel.
- Rear Buffered Outputs: Raw buffered signal, AC, and DC.
Alarm Setpoints and Alarm Time Delays:
- Alert and Danger: Configurable for each channel, with selectable normally open/closed contacts, delay settings, and hysteresis options.
- OK: Self-checking with green LED indicators.
Environmental and General:
- Front Plate: IP00, DIN 40050
- Climate: IP21, DIN 40050
- Operating Temperature: DIN 40040 class KTF
- Storage Temperature: 0°C - 65°C (32°F - 149°F)
- Relative Humidity: -30°C - 85°C (-22°F - 185°F)
- Vibration: Compliant with IEC 68-2, part 6
- Shock: Compliant with IEC 68-2, part 29
- EMC Resistance: EN50081-1 / EN50082-2
- Power Consumption: Max. 6 W, 250 mA at 24 VDC
- Configuration: Password protected
Dimensions and Weight:
- Dimensions (PCB/EURO card format): 100 x 160 mm (3.937 x 6.300 in)
- Width: 30.0 mm (1.181 in) (6 TE)
- Height: 128.4 mm (5.055 in) (3 HE)
- Length: 160.0 mm (6.300 in)
- Net Weight: Approximately 320 g (0.705 lbs)
- Gross Weight: Approximately 450 g (0.992 lbs) including standard packing
- Packing Volume: Approximately 2.5 dm3 (0.08 ft3)
Space Requirements:
- Occupies 1 slot in a 19" rack. Up to 14 modules can fit into each 19" rack.
Ordering Information:
- Model Number: A6140
- Product Description: Dual-channel Shaft Absolute Vibration Monitor
MORE EPRO Modules
| BRAND | Modules |
| EPRO | A6210 |
| EPRO | A6120 |
| EPRO | A6500-RC |
| EPRO | A6500-CC |
| EPRO | A6312/06 |
| EPRO | A6110 |
| EPRO | A6312 |
| Epro | A6125 |
| EPRO | A6220 |
| EPRO | A6410 |
| EPRO | A6370 |
| EPRO | A6370D |
| EPRO | A6140 |
| EPRO | A6740/10 |
| EPRO | A6824R |
| EPRO | A6312/08 |
Why Choose Us?
- Expertise: We’ve been in the business for over a decade, and our team knows the global supply market inside out.
- Global Network: Our extensive network of suppliers ensures that we can find what you need, no matter where it’s located.
- Competitive Pricing: We’re committed to offering you the best prices in the market.
- Speedy Delivery: We understand the importance of timely deliveries, and we’ll ensure your products reach you quickly.
Contact Information:
- Email: sales6@5gplc.com
- Business Hours: 24 hours a day, 7 days a week
- Address: No. 601, Hongwen Liuli, Siming District, Xiamen, China
Payment: T/T, Western Union.
Shipping port: Xiamen.
Lead time: Typically 1–3 working days after payment confirmation (subject to stock).
Worldwide delivery: We ship industrial automation parts to customers around the world. Freight is quoted with your RFQ.
F.A.Q.
Common questions about quotes, shipping, warranty and returnsClick Request a Quote on the product page and send us the part number, required quantity, and destination country. Our sales team will reply with current availability, pricing, and estimated delivery time.
In-stock items are normally prepared after payment and order confirmation. Most orders are dispatched from our warehouse in China, although the shipping location may vary depending on current stock.
Yes. We ship industrial automation parts to customers worldwide. Shipping cost and transit time depend on the destination, package weight, product size, and local import requirements.
We commonly use DHL, FedEx, UPS, and other international courier services. The carrier can be selected according to the destination, delivery speed, shipment size, and customer requirements.
Our products are generally covered by a 12-month warranty. Eligible products may also be returned under our 30-day refund policy. Please contact our team before returning any item to confirm the applicable terms and return instructions.
You may also like
Blog Posts
Industrial automation news, technical guides, and product updates.