The Honeywell FC-TPSU-2430 is a DC/DC power converter designed for the Honeywell Safety Manager system. It converts a nominal 24 VDC input into a regulated 30 VDC output rated at 1 A. The FC version is identified as a conformal-coated configuration, intended for power conversion in Safety Manager hardware installations.
Power Conversion Function
The FC-TPSU-2430 accepts an 18-36 VDC input and supplies a regulated 30 VDC output. This conversion provides a separate voltage level for compatible downstream equipment, including supported field termination assemblies (FTAs).
The output is rated at 1 A and is short-circuit proof. Output regulation and overvoltage protection help maintain the specified DC supply conditions for connected equipment.
Electrical Performance
The converter uses switching DC/DC conversion. Its input range accommodates variations around the nominal 24 VDC supply, while the regulated output maintains a defined voltage for the connected load.
The specified output ripple is less than 0.1 Vrms over 0-30 MHz, and load-and-line regulation is less than 1%. These values are relevant when checking the power requirements of downstream instrumentation and termination hardware.
Status Monitoring and Alarm Output
The module includes local LED indication and a read-back relay contact for output voltage monitoring. When the DC/DC output voltage is within the acceptable operating condition, the LED illuminates and the relay contact closes. This feedback allows the Safety Manager application to monitor the converter's power status.
The output distribution provides six pairs of terminals, allowing 30 VDC and 0 VDC connections to be distributed to supported FTA equipment. The converter also supports redundant external power arrangements when used with compatible termination assemblies.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | FC-TPSU-2430 |
| Brand | Honeywell |
| Product Type | DC/DC Power Supply Converter |
| System | Safety Manager |
| Nominal Input Voltage | 24 VDC |
| Input Voltage Range | 18-36 VDC |
| Maximum Inrush Current | 4 A |
| Output Voltage | 30 VDC +/- 0.25 V |
| Output Current | 1 A |
| Short-Circuit Current | Less than 3.3 A |
| Output Protection | Short-circuit proof |
| Output Ripple | Less than 0.1 Vrms (0-30 MHz) |
| Voltage Regulation | Less than 1% (load and line) |
| Overvoltage Protection | 31 V |
| Input-to-Output Isolation | 2000 VAC (1 min) |
| Efficiency | Greater than 75% |
| Switching Frequency | Greater than 25 kHz |
| Safety Class | Up to SIL 3 |
| MTBF | Approximately 400,000 hours |
| Status Indication | LED |
| Alarm Output | Read-back relay contact |
| Relay Contact Rating | 36 VDC / 40 mA; 30 VAC / 40 mA |
| Operating Temperature | -5 to +70 deg C |
| Storage Temperature | -40 to +85 deg C |
| Cooling | Natural convection |
| Mounting | TS32 / TS35 x 7.5 DIN rail |
| Module Dimensions | 150 x 70 x 62.3 mm (L x W x H) |
| Used Rail Length | 151 mm |
| Conformal Coating | Yes, FC configuration |
Installation and Connection Considerations
The FC-TPSU-2430 uses screw terminals for input power, output distribution and relay feedback. Its terminal arrangement includes:
- Terminals 3 and 4: 24 VDC input positive and negative.
- Terminals 1 and 2: Read-back relay contact.
- Terminals 1A/1B through 6A/6B: 30 VDC and 0 VDC output connections.
The 0 VDC output must be grounded to provide a predictable system response in the event of a field short circuit to earth. The input power must be switched off before connecting or removing the 24 VDC input conductors.
Frequently Asked Questions
Q: What is the difference between FC-TPSU-2430 and FS-TPSU-2430?
A: The FC configuration is conformal coated, while the FS configuration is non-conformal coated. The coating distinction is relevant when identifying the required hardware configuration for a Safety Manager installation.
Q: How does the FC-TPSU-2430 indicate an output power fault?
A: It uses an LED and a read-back relay contact to indicate output voltage status. When the output voltage is OK, the LED is on and the relay contact is closed. An abnormal voltage condition changes this indication.
Q: Which field termination assemblies can receive power from this converter?
A: The documented applications include the TSAI-1620m and TSHART-1620m analog input FTAs. These assemblies use an external 30 VDC supply for compatible transmitter power distribution.
Payment: T/T, Western Union.
Shipping port: Xiamen.
Lead time: Typically 1–3 working days after payment confirmation (subject to stock).
Worldwide delivery: We ship industrial automation parts to customers around the world. Freight is quoted with your RFQ.
F.A.Q.
Common questions about quotes, shipping, warranty and returnsClick Request a Quote on the product page and send us the part number, required quantity, and destination country. Our sales team will reply with current availability, pricing, and estimated delivery time.
In-stock items are normally prepared after payment and order confirmation. Most orders are dispatched from our warehouse in China, although the shipping location may vary depending on current stock.
Yes. We ship industrial automation parts to customers worldwide. Shipping cost and transit time depend on the destination, package weight, product size, and local import requirements.
We commonly use DHL, FedEx, UPS, and other international courier services. The carrier can be selected according to the destination, delivery speed, shipment size, and customer requirements.
Our products are generally covered by a 12-month warranty. Eligible products may also be returned under our 30-day refund policy. Please contact our team before returning any item to confirm the applicable terms and return instructions.
You may also like
Blog Posts
Industrial automation news, technical guides, and product updates.