Configured for Ethernet RIO communication in a Modicon X80 remote I/O architecture, the Schneider Electric BMECRA31210 (BMECRA31210 Ethernet RIO drop adaptor) provides physical and network interfacing between remote I/O modules and the Ethernet RIO network.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | BMECRA31210 |
| Brand | Schneider Electric |
| Series | Modicon X80 |
| Product Type | Ethernet RIO drop adaptor |
| Application | Remote I/O modules |
| Origin | US |
| Weight | 0.225 kg |
| Dimensions | 32 x 100 x 87.5 mm |
| Operating Temp | 0 to 60 deg C |
| Storage Temp | -40 to 85 deg C |
| Power Consumption | 1800 mA |
| Input Voltage | 3.3 VDC |
| Ethernet Ports | 3 RJ45 |
| Ethernet RIO Ports | 2 |
| Service Port | 1 |
| Transmission Rate | 10/100 Mbit/s |
| Ethernet Interface | 10/100BASE-TX |
| Communication Protocol | EtherNet/IP |
| Network Topology | Ring, RSTP |
| Communication Type | Half duplex, full duplex, autonegotiation, auto MDIX |
| Backplane Bus | Bus X and Ethernet |
| Communication Services | EtherNet/IP adapter, RSTP, QoS, CIP Explicit Messaging, Modbus TCP diagnostics |
| Network Services | DHCP, TFTP, FTP, FDR, SNTP, SNMP |
| Time Stamping | 10 ms |
| Protection Rating | IP20 |
| Mounting | Rack-mounted, screw fixing |
| Relative Humidity | 95% without condensation |
| Maximum Operating Altitude | 2000 m |
| Certifications | CE, UL, CSA, RCM, EAC, Merchant Navy |
Ethernet Backplane and RIO Network Characteristics
The BMECRA31210 provides three RJ45 interfaces, including two Ethernet RIO network ports and one service or distributed equipment port. The remote backplane supports Bus X and Ethernet communication for connected Modicon X80 modules.
EtherNet/IP provides device communication, while RSTP supports ring topology operation. QoS, CIP Explicit Messaging, and diagnostic services support communication and module-level supervision.
The adaptor supports 10/100BASE-TX transmission with autonegotiation and auto MDIX. Port communication can be enabled or disabled for network configuration and cybersecurity control.
The module supports remote I/O data collection and output data updates through the remote I/O head adaptor. Port mirroring, Device DDT diagnostics, system time stamping, and configuration changes on the fly are also provided.
The specified 10 ms time-stamping function records event timing for supported remote I/O operations. Compatibility includes discrete, analog, counter, HART, weighing, motion, frequency, serial, fiber converter, and other X80 modules.
Frequently Asked Questions
Q: What Ethernet interfaces are provided by the BMECRA31210?
A: The module provides three RJ45 ports, with two Ethernet RIO network ports and one service or distributed equipment port.
Q: What power requirement is specified for this adaptor?
A: The specified input voltage is 3.3 VDC, with a current consumption of 1800 mA.
Q: What environmental operating range is specified?
A: The specified ambient operating temperature range is 0 to 60 deg C, with IP20 protection.
Field Installation Guidelines
Install the BMECRA31210 in the designated Modicon X80 rack position and secure the module using the specified screw fixing arrangement.
Verify the rack backplane is correctly seated before energizing the system. Confirm that the module receives its specified backplane supply through the X80 architecture.
Connect Ethernet RIO cables only to the designated RIO ports. Connect service or distributed-equipment traffic through the appropriate service port.
Use shielded Ethernet cabling where required by the installation environment. Maintain physical separation between Ethernet communication wiring and high-current power conductors to reduce electromagnetic coupling.
Terminate cable shields according to the site grounding architecture and applicable Schneider Electric installation documentation. Avoid creating unintended shield-current paths between separately grounded equipment.
Check the RUN, ERR, Mod Status, Net Status, and STS indicators after startup. Confirm Ethernet link status and RIO network operation before commissioning connected I/O modules.
Do not exceed the specified operating temperature, humidity, altitude, or IP20 environmental limitations. IP20 protection does not provide protection against water ingress or conductive contamination.
Payment: T/T, Western Union.
Shipping port: Xiamen.
Lead time: Typically 1–3 working days after payment confirmation (subject to stock).
Worldwide delivery: We ship industrial automation parts to customers around the world. Freight is quoted with your RFQ.
F.A.Q.
Common questions about quotes, shipping, warranty and returnsClick Request a Quote on the product page and send us the part number, required quantity, and destination country. Our sales team will reply with current availability, pricing, and estimated delivery time.
In-stock items are normally prepared after payment and order confirmation. Most orders are dispatched from our warehouse in China, although the shipping location may vary depending on current stock.
Yes. We ship industrial automation parts to customers worldwide. Shipping cost and transit time depend on the destination, package weight, product size, and local import requirements.
We commonly use DHL, FedEx, UPS, and other international courier services. The carrier can be selected according to the destination, delivery speed, shipment size, and customer requirements.
Our products are generally covered by a 12-month warranty. Eligible products may also be returned under our 30-day refund policy. Please contact our team before returning any item to confirm the applicable terms and return instructions.
You may also like
Blog Posts
Industrial automation news, technical guides, and product updates.