The BMXDDI1602 is a 16-channel, 24 VDC discrete input module in the Schneider Electric Modicon X80 range. It receives signals from 2-wire or 3-wire DC sensors and transfers isolated input states to the PLC system. Positive logic (sink) input operation, channel-level LED indication, reverse-polarity protection and a 4 ms typical response time support its use in distributed and local I/O configurations.

Input Configuration and Signal Processing

The module provides 16 isolated digital input channels operating at 24 VDC. It supports both 2-wire and 3-wire sensor connections, with a nominal input current of 3.5 mA per channel at 24 VDC.

The input thresholds define the voltage levels recognized by the PLC:

  • Guaranteed logic 1: at least 11 V.
  • Guaranteed logic 0: 5 V or less.
  • Guaranteed logic 1 current: 2 mA.
  • Guaranteed logic 0 current: 1.5 mA.

The 6.8 kOhm input impedance determines the electrical load presented to connected sensors. Input parallelization is supported, and reverse-polarity protection helps protect the input circuitry against incorrect DC polarity.

Response Time and Diagnostics

The typical DC response time is 4 ms, with a maximum specified response time of 7 ms. These values are relevant when checking input timing against PLC scan requirements and the switching characteristics of connected field devices.

Local diagnostics include a green RUN LED for module operation, a green LED for each input channel, and red ERR and I/O indicators for module and I/O fault indication. The module also provides sensor supply voltage monitoring, with a sensor fault indication below 14 VDC and an OK indication above 18 VDC.

Modicon X80 Platform and Installation

The BMXDDI1602 belongs to the Modicon X80 common I/O platform used with Modicon M340 and M580 PLC architectures, including local and remote I/O configurations. Its 20-pin connection arrangement supports compatible removable screw-clamp, cage-clamp or spring-clamp terminal blocks.

The module is installed in an X80 module rack and secured with two screws. The supplied technical information specifies hot-swapping support. Confirm the applicable rack and system replacement procedures before exchanging a module in an operating installation.

Technical Specifications

Parameter Specification
Model BMXDDI1602
Brand Schneider Electric
Product Series Modicon X80
Product Type Discrete Input Module
Number of Inputs 16 isolated digital inputs
Input Voltage 24 VDC
Input Logic Positive logic (sink)
Input Current 3.5 mA at 24 VDC
Sensor Supply Voltage 19-30 VDC
Input Wiring 2-wire or 3-wire
Input Impedance 6,800 Ohm
Guaranteed Logic 1 Voltage >= 11 V
Guaranteed Logic 0 Voltage = 2 mA
Guaranteed Logic 0 Current 10 MOhm at 500 VDC
Channel Isolation 1,500 V for 1 minute
Power Dissipation 2.5 W
Hot Swapping Supported
Local Diagnostics RUN, ERR, I/O and individual channel LEDs
Mounting Modicon X80 module rack
Protection Rating IP20
Operating Temperature 0 to 60 deg C
Storage Temperature -40 to 85 deg C
Relative Humidity 5-95% at 55 deg C, non-condensing
Operating Altitude 0-2,000 m; derating required from 2,000 to 5,000 m
Vibration Resistance 3 Gn
Shock Resistance 30 Gn
Dimensions (H x W x D) 103.7 x 32 x 86 mm
Net Weight 0.115 kg
EAN 3595863910001
Total Lifecycle Carbon Footprint 32 kg CO2 eq.

Frequently Asked Questions

Q: Which sensors can be connected to the BMXDDI1602?

A: The module supports 2-wire and 3-wire DC proximity sensors conforming to IEC 60947-5-2. The sensor supply voltage must be within 19-30 VDC, and the input signal must satisfy the specified logic thresholds.

Q: What is the difference between the typical and maximum response times?

A: The typical response time is 4 ms, while the maximum specified response time is 7 ms. The maximum value should be considered when evaluating input detection timing and PLC application requirements.

Q: Can the BMXDDI1602 be replaced while the PLC system is operating?

A: Hot-swapping support is specified for this module. Actual replacement procedures must follow the applicable Modicon X80 rack and controller configuration requirements.

Payment: T/T, Western Union.

Shipping port: Xiamen.

Lead time: Typically 1–3 working days after payment confirmation (subject to stock).

Worldwide delivery: We ship industrial automation parts to customers around the world. Freight is quoted with your RFQ.

F.A.Q.

Common questions about quotes, shipping, warranty and returns

Click Request a Quote on the product page and send us the part number, required quantity, and destination country. Our sales team will reply with current availability, pricing, and estimated delivery time.

In-stock items are normally prepared after payment and order confirmation. Most orders are dispatched from our warehouse in China, although the shipping location may vary depending on current stock.

Yes. We ship industrial automation parts to customers worldwide. Shipping cost and transit time depend on the destination, package weight, product size, and local import requirements.

We commonly use DHL, FedEx, UPS, and other international courier services. The carrier can be selected according to the destination, delivery speed, shipment size, and customer requirements.

Our products are generally covered by a 12-month warranty. Eligible products may also be returned under our 30-day refund policy. Please contact our team before returning any item to confirm the applicable terms and return instructions.

Products FAQs

You may also like