Skip to product information
1 of 3

Schneider Electric BMXNOM0200 Modicon X80 Serial Communication Module

18 in stock
  • Manufacturer: Schneider
  • Product No.: BMXNOM0200
  • Country of origin: France
  • Product Type: Modicon X80 Serial Communication Module
  • Condition: Brand New
  • Payment: T/T, Western Union
  • Weight: 0.23 kg
  • Shipping port: Xiamen
  • Warranty: 12 months
  • Description
  • Reviews
  • Shipping & Payment

The Schneider Electric BMXNOM0200 is a Modicon X80 serial communication module equipped with two RS-232/RS-485 interfaces for Modbus and character-mode communication. It provides serial connectivity for Modicon M340 and M580 automation platforms, with RJ45 connections, internal rack power supply, and independent activity indicators for both serial ports.

Communication Interfaces and Protocols

The BMXNOM0200 provides two serial communication interfaces with different electrical configurations and transmission rates:

  • RS-232: RJ45 connector, 115.2 kbps, 8-wire connection.
  • RS-485: RJ45 connector, 57.6 kbps, one twisted-pair connection.
  • Communication modes: Modbus and character mode (ASCII).

The two interfaces allow the controller to exchange data with serial field devices and equipment. RS-232 supports point-to-point serial communication, while RS-485 provides a differential signaling interface suitable for multidrop serial networks. The actual network topology and device configuration must follow the applicable communication requirements.

Modicon X80 Platform Integration

The BMXNOM0200 belongs to the Modicon X80 modular I/O and communication platform. It is compatible with Modicon M340 and M580 PLC systems, providing serial communication within these automation architectures.

The module receives its operating power internally through the rack backplane. Its current consumption is 80 mA at 24 VDC, so no separate external power connection is specified for the module itself.

Status Indication and Diagnostics

Four LEDs provide local operating and communication status:

  • ERR (red): Indicates a module fault.
  • RUN (green): Indicates that the module is operating.
  • SER COM 0 (green): Indicates serial interface 0 activity.
  • SER COM 1 (green): Indicates serial interface 1 activity.

These indicators help maintenance personnel distinguish module operating status from serial communication activity during troubleshooting.

Technical Specifications

Parameter Specification
Model BMXNOM0200
Brand Schneider Electric
Product Range Modicon X80
Product Type Serial Communication Interface Module
Communication Interfaces 2 serial ports
Serial Interface 0 RS-232, RJ45, 115.2 kbps, 8 wires
Serial Interface 1 RS-485, RJ45, 57.6 kbps, 1 twisted pair
Communication Modes Modbus, Character Mode (ASCII)
Power Supply Internal power supply via module rack
Current Consumption 80 mA at 24 VDC
Local Diagnostics ERR, RUN, SER COM 0, SER COM 1 LEDs
Module Format Standard
Conformal Coating TC
Protection Rating IP20
Operating Temperature 0 to 60 deg C
Relative Humidity 10 to 95%, non-condensing
Weight 0.23 kg
Certifications CE, UL
Standards UL 508, EN 61131-2, EN 61000-6-4, EN 61000-6-2, EN 61010-2-201
EU Directives 2014/35/EU, 2014/30/EU
EAN 3595864024431
Lifecycle Carbon Footprint 101 kg CO2 eq.

Installation and Environmental Conditions

The BMXNOM0200 uses the standard Modicon X80 module format and obtains power through the module rack. Its IP20 protection rating indicates that it is intended for installation inside an appropriate electrical enclosure rather than direct exposure to water or dust.

The specified operating temperature range is 0 to 60 deg C, with relative humidity between 10% and 95%, provided that condensation does not occur. The TC conformal coating designation identifies its climatic treatment configuration.

Frequently Asked Questions

Q: Which PLC platforms support the BMXNOM0200?

A: The BMXNOM0200 is specified for use with Schneider Electric Modicon M340 and M580 PLC platforms. Confirm the rack configuration and applicable platform documentation before installation.

Q: Can the two serial ports operate at different communication speeds?

A: Yes. The specified interface rates are 115.2 kbps for RS-232 and 57.6 kbps for RS-485. Each interface has its own physical connection and activity indicator.

Q: Does the BMXNOM0200 require an external 24 VDC power supply?

A: No separate external supply is specified. The module receives power internally through the rack backplane and has a stated current consumption of 80 mA at 24 VDC.

Payment: T/T, Western Union.

Shipping port: Xiamen.

Lead time: Typically 1–3 working days after payment confirmation (subject to stock).

Worldwide delivery: We ship industrial automation parts to customers around the world. Freight is quoted with your RFQ.

F.A.Q.

Common questions about quotes, shipping, warranty and returns

Click Request a Quote on the product page and send us the part number, required quantity, and destination country. Our sales team will reply with current availability, pricing, and estimated delivery time.

In-stock items are normally prepared after payment and order confirmation. Most orders are dispatched from our warehouse in China, although the shipping location may vary depending on current stock.

Yes. We ship industrial automation parts to customers worldwide. Shipping cost and transit time depend on the destination, package weight, product size, and local import requirements.

We commonly use DHL, FedEx, UPS, and other international courier services. The carrier can be selected according to the destination, delivery speed, shipment size, and customer requirements.

Our products are generally covered by a 12-month warranty. Eligible products may also be returned under our 30-day refund policy. Please contact our team before returning any item to confirm the applicable terms and return instructions.

Products FAQs

You may also like