GE IS200ECTBG2ADE EX2100 Exciter Contact Terminal Board

11 în stoc
  • Manufacturer: General Electric
  • Product No.: IS200ECTBG2ADE
  • Product Type: EX2100 Exciter Contact Terminal Board
  • Condition: Complet nou
  • Payment: T/T, Western Union
  • Weight: 0.34 kg
  • Shipping port: Xiamen
  • Warranty: 12 luni
  • Descriere
  • Reviews
  • Livrare și plată

The GE IS200ECTBG2ADE is an Exciter Contact Terminal Board for the EX2100 excitation control system. It provides field contact input monitoring and relay output interfaces between external equipment and the excitation controller. Designed for simplex operation, the board handles trip contacts, general-purpose relay outputs, and auxiliary contact signals using separate relay control and contact wetting voltages.

Functional Description

The ECTB provides electrical interfaces for contact signals associated with generator excitation control. Its relay outputs allow the controller to operate external circuits, while its contact input circuits monitor the status of customer-supplied auxiliary contacts.

The board includes two trip relay outputs and four general-purpose Form-C relay outputs. The latter provide normally open, normally closed, and common terminals for external circuit switching. Relay operation is controlled by the excitation controller through the EMIO interface.

Contact Input and Relay Configuration

The contact input circuits use a nominal 70 V DC wetting supply to detect external contact states. This arrangement allows the controller to monitor auxiliary contacts and dedicated generator status and lockout signals.

The distinction between the board's voltage ratings is important: 24 V DC supplies the relay control circuits, 125 V DC is the nominal customer supply for relay contacts, and 70 V DC provides contact wetting for input monitoring. These voltages serve different circuit functions.

Relay Contact Ratings

The general-purpose relay contacts use a customer-supplied DC power circuit. Their breaking capacity depends on the load type and operating voltage, rather than being represented by a single universal current rating.

According to the EX2100 control guide, the general-purpose relay contact characteristics include:

  • Resistive load: 2 A at 28 V DC or 0.5 A at 125 V DC.
  • Inductive load: 1 A at 28 V DC or 0.1 A at 125 V DC.
  • Inductive load rating is specified at an L/R time constant of 0.007 s.
  • External suppression must be provided by the customer for inductive loads.

These ratings should be checked against the actual external load before connecting field circuits.

Technical Specifications

Parameter Specification
Model IS200ECTBG2ADE
Brand General Electric (GE)
Series EX2100
Product Type Exciter Contact Terminal Board
Operational Mode Simplex only
Trip Relay Outputs 2
General-Purpose Relay Outputs 4 Form-C
Auxiliary Contact Inputs 6
Dedicated Contact Inputs 52G, 86G
Relay Control Voltage 24 V DC
Customer Power 125 V DC nominal
Contact Wetting Voltage 70 V DC
Relay Break Characteristic 28 V DC
Weight 0.34 kg
Dimensions 150 x 76 x 90 mm

Simplex Configuration and System Interface

The ECTBG2 configuration is intended for simplex EX2100 control. Its contact signals are connected to the M1 controller, rather than being distributed across multiple controllers for redundant voting.

The distinction between ECTBG1 and ECTBG2 is important when identifying replacement hardware. ECTBG1 supports redundant control with a two-out-of-three relay voting arrangement, whereas ECTBG2 is designed for simplex operation. These configurations should not be treated as interchangeable.

Frequently Asked Questions

Q: Can the IS200ECTBG2ADE be used in a redundant EX2100 control system?

A: No. The ECTBG2 configuration is intended for simplex operation. The ECTBG1 version is used for redundant control and has a different controller interface and relay voting arrangement.

Q: What is the difference between the 24 V DC and 125 V DC supplies?

A: The 24 V DC supply operates the relay control circuits, while the nominal 125 V DC customer supply is switched through the relay contacts to external circuits. They perform different electrical functions and should not be interchanged.

Q: What is the purpose of the 70 V DC wetting voltage?

A: It provides the electrical excitation required to monitor external contact states. The board uses this voltage for auxiliary contact monitoring and dedicated 52G and 86G status inputs.

Plată: T/T, Western Union.

Port de expediere: Xiamen.

Termen de livrare: De obicei, 1–3 zile lucrătoare după confirmarea plății (în funcție de disponibilitatea stocului).

Livrare în întreaga lume: Expediem componente de automatizare industrială clienților din întreaga lume. Costul transportului este calculat împreună cu solicitarea dvs. de ofertă.

Întrebări frecvente

Întrebări frecvente despre oferte, livrare, garanție și retururi

Faceți clic pe Solicită o ofertă pe pagina produsului și trimiteți-ne numărul piesei, cantitatea necesară și țara de destinație. Echipa noastră de vânzări vă va răspunde cu informații despre disponibilitatea actuală, preț și timpul estimat de livrare.

Articolele aflate în stoc sunt, de obicei, pregătite după efectuarea plății și confirmarea comenzii. Majoritatea comenzilor sunt expediate din depozitul nostru din China, deși locația expedierii poate varia în funcție de stocul disponibil în prezent.

Da. Expediem componente pentru automatizări industriale clienților din întreaga lume. Costul transportului și timpul de livrare depind de destinație, greutatea coletului, dimensiunea produsului și cerințele locale de import.

Folosim în mod obișnuit DHL, FedEx, UPS și alte servicii internaționale de curierat. Transportatorul poate fi ales în funcție de destinație, viteza de livrare, dimensiunea expedierii și cerințele clientului.

Produsele noastre sunt, în general, acoperite de o garanție de 12 luni. Produsele eligibile pot fi, de asemenea, returnate în conformitate cu politica noastră de rambursare în termen de 30 de zile. Vă rugăm să contactați echipa noastră înainte de a returna orice produs pentru a confirma condițiile aplicabile și instrucțiunile de returnare.

Products FAQs

S-ar putea să-ți placă și acestea