Ugrás a termékinformációhoz
1 ból 3

Schneider Electric BMENOC0301C Modicon M580 Ethernet Communication Module

18 készleten
  • Manufacturer: Schneider
  • Product No.: BMENOC0301C
  • Country of origin: France
  • Product Type: Modicon M580 Ethernet Communication Module
  • Condition: Teljesen új
  • Payment: T/T, Western Union
  • Weight: 0.2 kg
  • Shipping port: Hsziamen
  • Warranty: 12 hónap
  • Leírás
  • Reviews
  • Szállítás és fizetés

Schneider Electric BMENOC0301C Modicon M580 Ethernet Communication Module

Configured for Ethernet communication between Modicon M580 controllers and network devices, the Schneider Electric BMENOC0301C (BMENOC0301C communication module) provides Modbus TCP and EtherNet/IP interface functions through three Ethernet ports.

Hardware Specifications

Parameter Specification
Model BMENOC0301C
Brand Schneider Electric
Product Range Modicon M580
Product Type Ethernet communication module
Compatible Controllers Modicon M580 standalone, redundant, and safety CPUs
Compatible Rack Modicon X80 rack with Ethernet backplane
Installation Position Main rack
Backplane Slot Ethernet + X-bus slot
Slots Occupied 1
Maximum Modules per Rack 4
Ethernet Ports 3
Ethernet Connectors RJ45
Ethernet Speed 10/100 Mbit/s
Transmission Mode Double-shielded twisted-pair cable
Communication Services Modbus TCP, EtherNet/IP, SNMP, FDR, RSTP, port mirroring
Integrated Switch Multi-port Ethernet switch
Web Server Commissioning, operation, and maintenance
Power Supply Internal rack power
Power Consumption 900 mA at 3.3 VDC for product version >= 13; 1800 mA at 3.3 VDC for product version < 13
Width 32 mm
Height 103.7 mm
Length 86 mm
Weight 0.2 kg
Operating Temp 0 to 60 deg C
IP Rating IP20
Conformal Coating Yes
Local Diagnostics RUN, ERR, ETH MS, and ETH NS LEDs
Certifications CE, UL, CSA, RCM, EAC, Marine, ATEX Zone 2/22, IECEx Zone 2/22
Standards IEC 61131-2, IEC 61010-2-201, IEC 61850-3, IEC 60079-0, and related listed standards

M580 Ethernet Network and Backplane Communication

The BMENOC0301C occupies one Ethernet + X-bus slot on the M580 main rack. It receives power through the rack internal power system and communicates through the Ethernet backplane.

Three RJ45 ports support 10/100 Mbit/s Ethernet communication. The integrated multi-port switch supports RSTP, port mirroring, bandwidth management, and Ethernet network services.

Modbus TCP I/O scanning and messaging, together with EtherNet/IP I/O scanning and messaging, provide controller-to-device data exchange. SNMP supports network management, while the FDR server provides device replacement-related network services.

The module supports M580 standalone CPUs, redundant CPUs, compatible safety CPUs, and X80 racks equipped with an Ethernet backplane.

Frequently Asked Questions (FAQ)

Q: How is the BMENOC0301C powered when installed in an M580 rack?
A: The module receives its operating power from the internal power distribution of the rack.

Q: What Ethernet interfaces are provided by the BMENOC0301C?
A: The module provides three RJ45 Ethernet ports supporting 10/100 Mbit/s transmission through double-shielded twisted-pair cabling.

Q: Does the BMENOC0301C support hot-swapping or field firmware replacement?
A: The supplied information does not specify hot-swap or firmware replacement conditions. Installation and firmware procedures should follow the applicable Schneider Electric documentation for the module revision.

Field Installation Guidelines

Install the BMENOC0301C in the designated Ethernet + X-bus position of the M580 main rack and secure the module according to the rack installation procedure.

Use shielded Ethernet cabling compatible with the RJ45 interfaces. Maintain physical separation between Ethernet cables and high-current, switching, or high-noise power conductors.

Terminate cable shields according to the system grounding design and Schneider Electric installation instructions. Avoid creating unintended shield-current paths between separately grounded equipment.

Verify rack power availability before insertion or removal. Confirm the module revision when applying the specified 3.3 VDC backplane current requirement.

After installation, inspect the RUN, ERR, ETH MS, and ETH NS indicators to verify processor, module, port configuration, and network status.

For installations in ATEX or IECEx Zone 2/22 environments, apply the applicable hazardous-location installation requirements and certified system configuration.

Fizetés: T/T, Western Union.

Szállítási kikötő: Hsziamen.

Átfutási idő: Általában 1–3 munkanap a fizetés visszaigazolását követően (készlettől függően).

Világszintű szállítás: Ipari automatizálási alkatrészeket szállítunk ügyfeleinknek világszerte. A szállítási költséget az ajánlatkérésével együtt adjuk meg.

GYIK.

Gyakori kérdések az árajánlatokról, a szállításról, a garanciáról és a visszaküldésről

A termékoldalon kattintson az Árajánlat kérése gombra, majd küldje el nekünk a cikkszámot, a szükséges mennyiséget és a célországot. Értékesítési csapatunk válaszol az aktuális elérhetőséggel, az árakkal és a várható szállítási idővel.

A raktáron lévő termékeket általában a fizetés és a rendelés visszaigazolása után készítjük elő. A legtöbb rendelést kínai raktárunkból küldjük ki, azonban a feladási hely az aktuális készlettől függően változhat.

Igen. Ipari automatizálási alkatrészeket szállítunk ügyfeleinknek világszerte. A szállítási költség és a szállítási idő a célállomástól, a csomag súlyától, a termék méretétől és a helyi importkövetelményektől függ.

Gyakran használjuk a DHL, FedEx, UPS és egyéb nemzetközi futárszolgálatokat. A fuvarozó a rendeltetési hely, a kézbesítés sebessége, a küldemény mérete és az ügyfél igényei alapján választható ki.

Termékeinkre általában 12 hónapos garancia vonatkozik. A jogosult termékek a 30 napos visszatérítési szabályzatunk alapján is visszaküldhetők. Bármely termék visszaküldése előtt lépjen kapcsolatba csapatunkkal az alkalmazandó feltételek és a visszaküldési útmutató megerősítése érdekében.

Products FAQs

Ez is tetszhet Önnek