Notificado por e-mail quando este produto estiver disponível
- Descrição
- Reviews
- Envio e pagamento
The Schneider Electric BMXDRA1605H is a 16-channel discrete relay output module in the Modicon X80 series. It provides normally open (NO) relay contacts for switching external AC or DC loads from a PLC control system. The module features a conformal coating, IP20 protection and an extended operating temperature range of -25 to 70 deg C for installations requiring additional environmental resistance.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | BMXDRA1605H |
| Brand | Schneider Electric |
| Series | Modicon X80 |
| Product Type | Discrete Relay Output Module |
| Number of Outputs | 16 |
| Output Type | Normally Open (NO) relay contacts |
| Discrete Output Logic | Positive |
| Rated Switching Current | 3 A |
| Switching Voltage | 24-240 VAC / 24-48 VDC |
| Minimum Switching Load | 1 mA at 5 VDC |
| Output Response Time | Less than 8 ms (activation); 10 ms (deactivation) |
| Insulation Resistance | Greater than 10 MOhm at 500 VDC |
| Dielectric Strength | 2000 VAC at 50/60 Hz for 1 minute |
| Protection Rating | IP20 |
| Protective Coating | Conformal coating |
| Operating Temperature | -25 to 70 deg C |
| Relative Humidity | 5-95% at 55 deg C, non-condensing |
| MTBF | 2,100,000 hours (source value; see editorial note) |
| Weight | 0.15 kg |
| EAN | 3595864025803 |
| Environmental Carbon Footprint | 148 kg CO2 eq. |
Relay Output Function
The BMXDRA1605H uses electromechanical relay contacts to switch external loads. The PLC controls the relay coils, while the relay contacts provide the switching path for the connected field circuits. Its 16 normally open outputs remain open when the corresponding relays are de-energized and close when activated.
The relay output arrangement supports both AC and DC switching within the specified voltage ranges. The minimum switching load of 1 mA at 5 VDC is a separate contact operating parameter and should not be confused with the maximum rated switching current.
Environmental Protection and Construction
This version has a conformal protective coating intended for environments with specified resistance requirements. The manufacturer lists gas resistance classifications Gx and 3C4, dust and sand resistance classifications 3S4, salt resistance Level 2, and mould resistance Class 3B2.
The IP20 rating describes protection against access to hazardous parts and solid foreign objects. It does not indicate protection against water ingress. The extended temperature range and environmental classifications should be considered when checking suitability for the actual control cabinet installation.
PLC Platform and Installation
The BMXDRA1605H belongs to the common Modicon X80 I/O platform used with Modicon M340 and Modicon M580 programmable automation controllers. It can be installed in local or remote I/O configurations, subject to the applicable rack and system configuration requirements.
The module uses a removable 20-pin terminal block for field wiring. Installation requires mounting the module on the appropriate rack and securing it with two screws. Compatible terminal block connection options include cage-clamp, screw-clamp and removable spring-clamp types.
Frequently Asked Questions
Q: What is the difference between BMXDRA1605H and BMXDRA1605?
A: Both references belong to the Modicon X80 16-channel relay output family. The BMXDRA1605H is the ruggedized version with conformal coating and an extended operating temperature range for more demanding environmental conditions.
Q: Which PLC platforms support the BMXDRA1605H?
A: The module is specified for Modicon M340 and Modicon M580 PLC platforms, including local and remote I/O configurations. The appropriate rack and terminal block must be selected for the installation.
Q: What protection should be considered when wiring the relay outputs?
A: Output circuit protection is required. Schneider Electric documentation specifies fast-acting fuses for output protection and recommends suitable discharge or suppression components according to the AC or DC load type. Verify the wiring diagram and load conditions before commissioning.
Pagamento: T/T, Western Union.
Porto de expedição: Xiamen.
Prazo de entrega: Normalmente, 1–3 dias úteis após a confirmação do pagamento (sujeito à disponibilidade em stock).
Entrega mundial: Enviamos peças de automação industrial para clientes em todo o mundo. Os custos de transporte são indicados no seu pedido de cotação.
Perguntas frequentes
Perguntas frequentes sobre orçamentos, envio, garantia e devoluçõesClique em Solicitar um orçamento na página do produto e envie-nos o número da peça, a quantidade necessária e o país de destino. A nossa equipa de vendas responderá com a disponibilidade atual, o preço e o prazo de entrega estimado.
Os artigos disponíveis em stock são normalmente preparados após o pagamento e a confirmação da encomenda. A maioria das encomendas é expedida do nosso armazém na China, embora o local de expedição possa variar consoante o stock disponível.
Sim. Enviamos peças de automação industrial para clientes em todo o mundo. O custo de envio e o tempo de trânsito dependem do destino, do peso da encomenda, do tamanho do produto e dos requisitos de importação locais.
Utilizamos habitualmente os serviços de correio expresso internacionais DHL, FedEx, UPS e outros. O transportador pode ser selecionado de acordo com o destino, a rapidez de entrega, o tamanho do envio e os requisitos do cliente.
Os nossos produtos estão geralmente cobertos por uma garantia de 12 meses. Os produtos elegíveis também podem ser devolvidos ao abrigo da nossa política de reembolso de 30 dias. Contacte a nossa equipa antes de devolver qualquer artigo para confirmar os termos aplicáveis e as instruções de devolução.
Também poderá gostar de
Publicações do blogue
Notícias sobre automação industrial, guias técnicos e atualizações de produtos.