Ir para as informações do produto
1 de 3

Schneider Electric BMEP583040 Modicon M580 Processor Module

18 em stock
  • Manufacturer: Schneider
  • Product No.: BMEP583040
  • Country of origin: France
  • Product Type: Modicon M580 Processor Module
  • Condition: Completamente novo
  • Payment: T/T, Western Union
  • Weight: 0.849 kg
  • Shipping port: Xiamen
  • Warranty: 12 meses
  • Descrição
  • Reviews
  • Envio e pagamento

Configured for processor execution, local I/O management, and Ethernet TCP/IP communication in the Modicon M580 PAC platform, the Schneider Electric BMEP583040 (BMEP583040 Processor Module) provides rack-based control processing with integrated Ethernet service and device-network interfaces. It supports up to 8 racks, 3072 discrete local I/O, 768 analog local I/O, 16 remote I/O stations, and 64 distributed devices.

Hardware Specifications

Parameter Specification
Model BMEP583040
Brand Schneider Electric
Series Modicon M580
Product Type Processor Module
Origin US
Weight 0.849 kg
Operating Temp 0 to 60 deg C
Power Consumption 295 mA at 24 VDC
Rack Capacity 8 racks
Local Discrete I/O 3072 I/O
Local Analog I/O 768 I/O
Application-Specific Channels 108
Remote I/O Stations 16, 2 remote drops per I/O station
Distributed Equipment 64
Ethernet Interfaces 1 Ethernet TCP/IP service port; 2 Ethernet TCP/IP device-network ports
USB Interface USB type Mini-B
Program Memory 12 MB integrated RAM
Data Memory 1024 kB integrated RAM
System Memory 10 kB integrated RAM
Flash Storage 4 GB expandable flash
Communication Services RIO scanner, DIO scanner
Processing Capacity 30 Kinst/ms at 65% Boolean + 35% fixed arithmetic; 40 Kinst/ms at 100% Boolean
MTBF 775000 h
Protection Rating IP20
Storage Temp -40 to 85 deg C
Vibration Resistance 3 gn
Shock Resistance 30 gn
Relative Humidity 5 to 95% at 55 deg C, non-condensing
Operating Altitude 0 to 2000 m; 2000 to 5000 m with derating
Certifications CE, UL, CSA, RCM, EAC, Merchant Navy, UKCA
Standards IEC 61131-2, IEC 61010-2-201, UL 61010-2-201, CSA C22.2 No 61010-2-201, IACS E10, EN/IEC 61000-6-5, EN/IEC 61850-3

Ethernet and I/O Processing

The BMEP583040 separates Ethernet service communication from device-network communication through dedicated TCP/IP interfaces. The processor provides RIO and DIO scanner functions for remote and distributed I/O management. The rack-based architecture supplies internal power to the processor and connected modules, while the processor manages local I/O resources and application execution.

The module supports application-specific functions including serial link, motion control, counter, SSI encoder, HART, and accurate time stamping. Its application structure includes auxiliary tasks, cyclic or periodic master tasks, event tasks, and a periodic fast task.

Frequently Asked Questions

Q: What power connection is used by the BMEP583040?

A: The processor receives its operating power internally through the rack. The specified processor current consumption is 295 mA at 24 VDC.

Q: How many Ethernet interfaces are integrated into the processor?

A: The module provides one Ethernet TCP/IP service port and two Ethernet TCP/IP device-network ports. A USB type Mini-B interface is also provided.

Q: What local and remote I/O capacity is specified?

A: The processor supports up to 3072 discrete local I/O, 768 analog local I/O, and 16 remote I/O stations. The specified distributed equipment capacity is 64 devices.

Field Installation Guidelines

Install the processor in the designated Modicon M580 rack position and ensure that the rack power and backplane connections are correctly seated before energizing the system. Confirm that the processor is mechanically secured and that adjacent modules do not obstruct ventilation or access to status indicators.

Route Ethernet communication cables separately from high-current power conductors and switching circuits where practical. Maintain proper cable shielding and grounding practices according to the installation design and applicable M580 documentation.

Before commissioning, verify the Ethernet port assignment, device-network topology, rack configuration, and I/O addressing against the application configuration. Check the RUN, ERR, I/O, DL, BACKUP, and Ethernet status indicators after startup to identify processor, I/O, memory, or network conditions.

Pagamento: T/T, Western Union.

Porto de expedição: Xiamen.

Prazo de entrega: Normalmente, 1–3 dias úteis após a confirmação do pagamento (sujeito à disponibilidade em stock).

Entrega mundial: Enviamos peças de automação industrial para clientes em todo o mundo. Os custos de transporte são indicados no seu pedido de cotação.

Perguntas frequentes

Perguntas frequentes sobre orçamentos, envio, garantia e devoluções

Clique em Solicitar um orçamento na página do produto e envie-nos o número da peça, a quantidade necessária e o país de destino. A nossa equipa de vendas responderá com a disponibilidade atual, o preço e o prazo de entrega estimado.

Os artigos disponíveis em stock são normalmente preparados após o pagamento e a confirmação da encomenda. A maioria das encomendas é expedida do nosso armazém na China, embora o local de expedição possa variar consoante o stock disponível.

Sim. Enviamos peças de automação industrial para clientes em todo o mundo. O custo de envio e o tempo de trânsito dependem do destino, do peso da encomenda, do tamanho do produto e dos requisitos de importação locais.

Utilizamos habitualmente os serviços de correio expresso internacionais DHL, FedEx, UPS e outros. O transportador pode ser selecionado de acordo com o destino, a rapidez de entrega, o tamanho do envio e os requisitos do cliente.

Os nossos produtos estão geralmente cobertos por uma garantia de 12 meses. Os produtos elegíveis também podem ser devolvidos ao abrigo da nossa política de reembolso de 30 dias. Contacte a nossa equipa antes de devolver qualquer artigo para confirmar os termos aplicáveis e as instruções de devolução.

Products FAQs

Também poderá gostar de