Product Overview

The 5437-1124 overspeed protection module is a critical safety component developed by Woodward for the ProTech-GII turbine protection platform. It is engineered to continuously supervise shaft speed and acceleration on high-energy rotating equipment and to trigger an immediate shutdown when unsafe operating limits are exceeded.

Designed as a plug-in, field-replaceable unit, this module forms part of a triple-redundant architecture that minimizes nuisance trips while maintaining strict compliance with turbine safety integrity requirements. The design is widely deployed in power generation and heavy industrial turbine installations where failure prevention is mandatory.

Core Functions and Capabilities

The 5437-1124 module provides deterministic overspeed detection using configurable trip algorithms and redundant logic paths. When installed in a ProTech-GII chassis, it participates in a 2-out-of-3 voting scheme, allowing a shutdown decision only when two independent channels confirm an unsafe condition.

Key functional characteristics include continuous speed validation, fault diagnostics, and non-volatile event storage. The module supports multiple speed sensing technologies, enabling compatibility with both legacy and modern turbine instrumentation.

Technical Specifications

General

  • Manufacturer: Woodward
  • Product Family: ProTech-GII
  • Module Type: Overspeed / Over-acceleration Protection
  • Country of Manufacture: United States
  • Installation: ProTech-GII rack-mounted, hot-swappable design

Electrical Characteristics

  • Supply Voltage: 24 VDC nominal
  • Operating Range: 18 to 32 VDC
  • Power Consumption: Low-power safety module design
  • Isolation: Internal galvanic isolation between inputs and logic circuits

Speed Input Interfaces

  • Magnetic Pickup (MPU) sensors
  • Proximity probes with speed signal conditioning
  • Redundant input validation and signal plausibility checks

Protection Logic

  • User-configurable overspeed setpoints
  • Independent acceleration monitoring
  • 2oo3 voting when used in triple-module configurations
  • Fail-safe behavior on internal diagnostics failure

Communication and Outputs

  • System Communication: ProTech-GII internal safety bus
  • External Integration: Modbus TCP/RTU via system interface modules
  • Discrete trip outputs through system-level safety relays
  • Event and alarm data accessible from DCS or asset management systems

Environmental Ratings

  • Operating Temperature: –40 °C to +85 °C
  • Storage Temperature: –55 °C to +105 °C
  • Vibration and Shock: Designed for turbine skid environments
  • Enclosure Protection: Determined by ProTech-GII chassis (not IP-rated as a standalone module)

System Compatibility

The 5437-1124 is fully compatible with Woodward ProTech-GII turbine protection systems used on:

  • Steam turbines
  • Gas turbines
  • Hydro turbines
  • Mechanical drive turbines in refining and petrochemical plants

It operates independently from the turbine governor, ensuring that overspeed protection remains active even if control functions fail.

Typical Applications

  • Utility-scale power generation turbines
  • Combined-cycle power plants
  • Oil & gas compression trains
  • Pipeline pump and compressor drives
  • Critical rotating equipment requiring SIL-rated overspeed protection

Frequently Asked Questions

Is the 5437-1124 a standalone controller? No. This module functions only within a ProTech-GII protection system and cannot operate independently.

Does it replace a governor overspeed function? No. It provides an independent mechanical safety layer, separate from turbine control or fuel management systems.

Can it be used in SIL-rated architectures? Yes. When configured in a triple-modular ProTech-GII system, it supports high-integrity safety applications.

Pagamento: T/T, Western Union.

Porto de expedição: Xiamen.

Prazo de entrega: Normalmente, 1–3 dias úteis após a confirmação do pagamento (sujeito à disponibilidade em stock).

Entrega mundial: Enviamos peças de automação industrial para clientes em todo o mundo. Os custos de transporte são indicados no seu pedido de cotação.

Perguntas frequentes

Perguntas frequentes sobre orçamentos, envio, garantia e devoluções

Clique em Solicitar um orçamento na página do produto e envie-nos o número da peça, a quantidade necessária e o país de destino. A nossa equipa de vendas responderá com a disponibilidade atual, o preço e o prazo de entrega estimado.

Os artigos disponíveis em stock são normalmente preparados após o pagamento e a confirmação da encomenda. A maioria das encomendas é expedida do nosso armazém na China, embora o local de expedição possa variar consoante o stock disponível.

Sim. Enviamos peças de automação industrial para clientes em todo o mundo. O custo de envio e o tempo de trânsito dependem do destino, do peso da encomenda, do tamanho do produto e dos requisitos de importação locais.

Utilizamos habitualmente os serviços de correio expresso internacionais DHL, FedEx, UPS e outros. O transportador pode ser selecionado de acordo com o destino, a rapidez de entrega, o tamanho do envio e os requisitos do cliente.

Os nossos produtos estão geralmente cobertos por uma garantia de 12 meses. Os produtos elegíveis também podem ser devolvidos ao abrigo da nossa política de reembolso de 30 dias. Contacte a nossa equipa antes de devolver qualquer artigo para confirmar os termos aplicáveis e as instruções de devolução.

Products FAQs

Também poderá gostar de