Schneider Electric 47600 MicroLogic 2.0E Control Unit
Configured for overload and instantaneous short-circuit protection in MasterPact circuit breaker systems, the Schneider Electric 47600 (47600 Control Unit) provides direct electrical execution. The unit integrates MicroLogic 2.0E electronic trip functionality with energy metering capability, supporting protection parameter adjustment, fault indication, and measurement readout within MasterPact NT/NW, Compact NS, and Masterpact MT platforms.
Suffix Breakdown & Model Matrix
The supplied documentation identifies a single catalog number, 47600, associated with the MicroLogic 2.0E electronic trip unit. No official suffix subdivision or ordering matrix is specified in the provided data.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 47600 |
| Brand | Schneider Electric |
| Product Type | Electronic Control Unit |
| Trip Unit Name | MicroLogic 2.0E |
| Trip Unit Technology | Electronic |
| Application | Distribution Protection |
| Compatible Platforms | MasterPact NT, MasterPact NW, Compact NS, Masterpact MT |
| Number of Poles | 3P, 4P |
| Protected Pole Configurations | 3t, 4t, 3t + N/2 |
| Protection Functions | Long-Time Overload, Instantaneous Short-Circuit |
| Long-Time Pickup Range (Ir) | 0.4 to 1 x In |
| Long-Time Delay Range (tr) | 0.7 to 16.6 s at 7.2 x Ir; 0.7 to 24 s at 6 x Ir; 12.5 to 600 s at 1.5 x Ir |
| Instantaneous Pickup Range (Ii) | 1.5 to 10 x Ir |
| Thermal Memory | 20 min |
| Measurement Type | Energy Meter |
| Data Communication | Measurement Readout, Protection Settings, Alarm Settings |
| Local Indication | 3 Fault LEDs, 1 Internal Error LED |
| Display Type | Digital Display |
| Network Type | AC |
| Network Frequency | 50/60 Hz |
| Mounting Mode | Fixed, Drawout |
| Operating Temp | -25 to 70 deg C |
| Storage Temp | -40 to 85 deg C |
| Dimensions | 21.7 cm x 8.0 cm x 6.6 cm |
| Weight | 273 g |
Profinet and Backplane Integration Considerations
Within Schneider Electric breaker protection architectures, the MicroLogic 2.0E control unit exchanges operational data related to metering, alarm status, and protection settings. Firmware compatibility between the trip unit and the host breaker assembly should be verified before replacement activities. Parameter synchronization, trip rating selection, and protection configuration must match the installed breaker frame and rated current setting to maintain protection coordination.
The electronic protection platform supports adjustable pickup and delay characteristics, allowing I/O density scaling across multiple breaker ratings ranging from 630 A to 6300 A without changing the fundamental protection philosophy of the installation.
Frequently Asked Questions
Q: Does the 47600 MicroLogic 2.0E support hot replacement while the breaker remains energized? A: The provided documentation does not specify hot-swap capability. Replacement procedures should follow the applicable MasterPact maintenance instructions and site lockout requirements.
Q: Can the protection settings be adjusted locally? A: Yes. The unit provides adjustable long-time and instantaneous protection settings through the electronic trip unit interface and digital display.
Q: Is earth-fault protection included in this model? A: No. The supplied specification identifies overload and instantaneous short-circuit protection only and lists earth-leakage protection as unavailable.
Field Installation Guidelines
- Verify breaker frame compatibility before installing the control unit into MasterPact NT, NW, MT, or compatible Compact NS assemblies.
- De-energize equipment and follow lockout/tagout procedures prior to removal or insertion of the trip unit.
- Inspect connector contacts and backplane interfaces for contamination, oxidation, or mechanical damage before installation.
- Maintain separation between power conductors and low-level communication wiring to reduce conducted electrical noise.
- Confirm that current rating, pickup settings, and delay settings correspond to the protection study for the distribution system.
- After commissioning, verify LED indication, display operation, and trip parameter configuration through functional testing procedures.
Ödəniş: T/T, Western Union.
Göndərmə limanı: Syamen.
Hazırlanma müddəti: Adətən ödəniş təsdiqləndikdən sonra 1–3 iş günü (stokdan asılıdır).
Dünya üzrə çatdırılma: Sənaye avtomatlaşdırma hissələrini dünyanın hər yerindəki müştərilərə göndəririk. Daşıma haqqı sorğunuzla birlikdə hesablanır.
Tez-tez verilən suallar
Təkliflər, çatdırılma, zəmanət və qaytarılma ilə bağlı tez-tez verilən suallarMəhsul səhifəsində Təklif tələb edin düyməsinə klikləyin və bizə hissə nömrəsini, tələb olunan miqdarı və təyinat ölkəsini göndərin. Satış komandamız mövcudluq, qiymət və təxmini çatdırılma müddəti barədə sizə cavab verəcək.
Anbarda olan məhsullar adətən ödəniş və sifariş təsdiqləndikdən sonra hazırlanır. Sifarişlərin əksəriyyəti Çindəki anbarımızdan göndərilir, lakin göndərilmə yeri mövcud ehtiyatdan asılı olaraq dəyişə bilər.
Bəli. Sənaye avtomatlaşdırma hissələrini dünya üzrə müştərilərə göndəririk. Çatdırılma xərci və müddəti təyinat yerindən, bağlamanın çəkisindən, məhsulun ölçüsündən və yerli idxal tələblərindən asılıdır.
Biz adətən DHL, FedEx, UPS və digər beynəlxalq kuryer xidmətlərindən istifadə edirik. Daşıyıcı təyinat yerinə, çatdırılma sürətinə, göndərişin ölçüsünə və müştərinin tələblərinə uyğun olaraq seçilə bilər.
Məhsullarımız ümumiyyətlə 12 aylıq zəmanət ilə təmin olunur. Uyğun məhsullar həmçinin 30 günlük geri ödəniş siyasətimizə əsasən qaytarıla bilər. Tətbiq olunan şərtləri və qaytarma təlimatlarını təsdiqləmək üçün hər hansı məhsulu qaytarmadan əvvəl komandamızla əlaqə saxlayın.
Bəyənə biləcəyiniz digər məhsullar
Bloq yazıları
Sənaye avtomatlaşdırılması xəbərləri, texniki təlimatlar və məhsul yenilikləri.