Upozornit e-mailem, jakmile bude tento produkt dostupný
- Popis
- Reviews
- Doprava a platba
Product Description
The Schneider Electric 140DRA84000 is a relay-based discrete output module developed for the Modicon Quantum PLC platform. This standard-format module provides 16 isolated relay output channels, each configured with a single normally open (NO) contact for dependable switching of AC and DC loads in industrial automation systems.
Designed for mixed-voltage control applications, the 140DRA84000 supports output ranges from 20–250 V AC and 5–150 V DC, allowing integration with relays, contactors, pilot devices, alarms, and electromechanical loads. The module combines high electrical durability with internal overvoltage suppression, making it suitable for continuous-duty industrial environments.
Each output channel uses Form A relay contacts and includes status indication through dedicated front-panel LEDs. The module also features reinforced isolation between channels and the backplane bus, improving operational safety and reducing electrical interference in control cabinets.
Schneider Electric discontinued the 140DRA84000 relay module in January 2023. Long-term service support is expected through December 2030. The officially recommended replacement is the Modicon X80 BMXDRA0815 relay output module.
Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | Schneider Electric |
| Model Number | 140DRA84000 |
| Product Series | Modicon Quantum |
| Product Type | Relay Discrete Output Module |
| Output Channels | 16 Relay Outputs |
| Contact Configuration | 1 NO per Channel |
| Contact Form | Form A |
| Output Voltage Range | 20–250 V AC |
| DC Output Range | 30–150 V DC / 5–30 V DC |
| Addressing Requirement | 1 Output Word |
| Maximum Resistive Load | 2 A at 250 V AC/DC |
| Maximum Motor Load | 1 A, 1/8 hp |
| Tungsten Load Rating | 1 A |
| Capacitive Surge Current | 10 A for 10 ms |
| Switching Capacity | 500 VA Resistive |
| Response Time OFF to ON | 10 ms |
| Response Time ON to OFF | 20 ms |
| Minimum Load Current | 50 mA |
| Mechanical Life Expectancy | 10 Million Operations |
| Electrical Endurance | Up to 200,000 Cycles |
| Overvoltage Protection | Internal Varistor, 275 V |
| Isolation Between Channels | 1780 Vrms |
| Bus-to-Channel Isolation | 1780 Vrms AC / 2500 V DC |
| Bus Current Consumption | 1100 mA |
| Power Dissipation | 5.5 W + Load Contribution |
| Diagnostic Indicators | Active LED, Fault LED, 16 Output LEDs |
| Operating Temperature | 0°C to 60°C |
| Storage Temperature | -40°C to 85°C |
| Humidity Rating | 95% Non-Condensing |
| Maximum Operating Altitude | 5000 m |
| Mounting Format | Standard Quantum Rack Module |
| Net Weight | 0.45 kg |
| Compliance Standards | UL 508, CSA C22.2 No.142 |
| Certifications | CE, FM Class 1 Div 2, ABS, GOST, C-Tick |
Operational Characteristics
- 16 relay-based discrete outputs for AC/DC switching
- Form A normally open contact configuration
- Compatible with Modicon Quantum backplanes
- Integrated varistor protection against voltage spikes
- High relay endurance for repetitive industrial operations
- LED diagnostics for channel activity and module status
- Suitable for resistive, inductive, and pilot-duty loads
- Standard Quantum housing for easy rack installation
Recommended Replacement Model
The discontinued 140DRA84000 can be replaced with:
- BMXDRA0815 — Modicon X80 relay output module with 8 NO relay outputs
Migration planning should include I/O mapping and rack compatibility verification when upgrading from Quantum to X80 platforms.
Typical Industrial Applications
- PLC relay output expansion
- Process control systems
- Motor starter interfacing
- Alarm and annunciator systems
- Industrial panel automation
- HVAC control systems
- Water treatment facilities
- Packaging and conveyor equipment
FAQ
What type of outputs does the 140DRA84000 use?
The module uses electromechanical relay outputs with normally open Form A contacts.
Can the module switch both AC and DC loads?
Yes. The module supports AC loads up to 250 V and DC loads up to 150 V depending on application current requirements.
Is surge suppression included?
Yes. Internal varistor-based overvoltage protection is integrated to reduce relay contact stress caused by transient spikes.
Is the 140DRA84000 still manufactured?
No. Schneider Electric discontinued this model in 2023, although support service remains available until 2030.
Platba: T/T, Western Union.
Přístav odeslání: Xiamen.
Dodací lhůta: Obvykle 1–3 pracovní dny po potvrzení platby (v závislosti na skladových zásobách).
Celosvětové doručení: Dodáváme díly pro průmyslovou automatizaci zákazníkům po celém světě. Cena přepravy bude uvedena v naší nabídce na základě vaší poptávky.
Často kladené otázky
Časté otázky týkající se cenových nabídek, dopravy, záruky a vrácení zbožíNa stránce produktu klikněte na Požádat o cenovou nabídku a zašlete nám číslo dílu, požadované množství a cílovou zemi. Náš prodejní tým vám odpoví s informacemi o aktuální dostupnosti, ceně a odhadované době dodání.
Položky skladem se obvykle připravují po zaplacení a potvrzení objednávky. Většina objednávek se odesílá z našeho skladu v Číně, ačkoli místo odeslání se může lišit v závislosti na aktuálním stavu zásob.
Ano. Zasíláme díly pro průmyslovou automatizaci zákazníkům po celém světě. Náklady na dopravu a doba přepravy závisí na místě určení, hmotnosti zásilky, velikosti produktu a místních dovozních požadavcích.
Obvykle využíváme DHL, FedEx, UPS a další mezinárodní kurýrní služby. Dopravce lze vybrat podle místa určení, rychlosti doručení, velikosti zásilky a požadavků zákazníka.
Na naše výrobky se obecně vztahuje 12měsíční záruka. Způsobilé výrobky lze také vrátit v rámci našich 30denních podmínek pro vrácení peněz. Před vrácením jakékoli položky kontaktujte náš tým a ověřte si platné podmínky a pokyny k vrácení.
Mohlo by se vám také líbit
Příspěvky na blogu
Novinky z oblasti průmyslové automatizace, technické příručky a aktualizace produktů.