Schneider Electric BMENOC0301C Modicon M580 Ethernet Communication Module
Configured for Ethernet communication between Modicon M580 controllers and network devices, the Schneider Electric BMENOC0301C (BMENOC0301C communication module) provides Modbus TCP and EtherNet/IP interface functions through three Ethernet ports.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | BMENOC0301C |
| Brand | Schneider Electric |
| Product Range | Modicon M580 |
| Product Type | Ethernet communication module |
| Compatible Controllers | Modicon M580 standalone, redundant, and safety CPUs |
| Compatible Rack | Modicon X80 rack with Ethernet backplane |
| Installation Position | Main rack |
| Backplane Slot | Ethernet + X-bus slot |
| Slots Occupied | 1 |
| Maximum Modules per Rack | 4 |
| Ethernet Ports | 3 |
| Ethernet Connectors | RJ45 |
| Ethernet Speed | 10/100 Mbit/s |
| Transmission Mode | Double-shielded twisted-pair cable |
| Communication Services | Modbus TCP, EtherNet/IP, SNMP, FDR, RSTP, port mirroring |
| Integrated Switch | Multi-port Ethernet switch |
| Web Server | Commissioning, operation, and maintenance |
| Power Supply | Internal rack power |
| Power Consumption | 900 mA at 3.3 VDC for product version >= 13; 1800 mA at 3.3 VDC for product version < 13 |
| Width | 32 mm |
| Height | 103.7 mm |
| Length | 86 mm |
| Weight | 0.2 kg |
| Operating Temp | 0 to 60 deg C |
| IP Rating | IP20 |
| Conformal Coating | Yes |
| Local Diagnostics | RUN, ERR, ETH MS, and ETH NS LEDs |
| Certifications | CE, UL, CSA, RCM, EAC, Marine, ATEX Zone 2/22, IECEx Zone 2/22 |
| Standards | IEC 61131-2, IEC 61010-2-201, IEC 61850-3, IEC 60079-0, and related listed standards |
M580 Ethernet Network and Backplane Communication
The BMENOC0301C occupies one Ethernet + X-bus slot on the M580 main rack. It receives power through the rack internal power system and communicates through the Ethernet backplane.
Three RJ45 ports support 10/100 Mbit/s Ethernet communication. The integrated multi-port switch supports RSTP, port mirroring, bandwidth management, and Ethernet network services.
Modbus TCP I/O scanning and messaging, together with EtherNet/IP I/O scanning and messaging, provide controller-to-device data exchange. SNMP supports network management, while the FDR server provides device replacement-related network services.
The module supports M580 standalone CPUs, redundant CPUs, compatible safety CPUs, and X80 racks equipped with an Ethernet backplane.
Frequently Asked Questions (FAQ)
Q: How is the BMENOC0301C powered when installed in an M580 rack?
A: The module receives its operating power from the internal power distribution of the rack.
Q: What Ethernet interfaces are provided by the BMENOC0301C?
A: The module provides three RJ45 Ethernet ports supporting 10/100 Mbit/s transmission through double-shielded twisted-pair cabling.
Q: Does the BMENOC0301C support hot-swapping or field firmware replacement?
A: The supplied information does not specify hot-swap or firmware replacement conditions. Installation and firmware procedures should follow the applicable Schneider Electric documentation for the module revision.
Field Installation Guidelines
Install the BMENOC0301C in the designated Ethernet + X-bus position of the M580 main rack and secure the module according to the rack installation procedure.
Use shielded Ethernet cabling compatible with the RJ45 interfaces. Maintain physical separation between Ethernet cables and high-current, switching, or high-noise power conductors.
Terminate cable shields according to the system grounding design and Schneider Electric installation instructions. Avoid creating unintended shield-current paths between separately grounded equipment.
Verify rack power availability before insertion or removal. Confirm the module revision when applying the specified 3.3 VDC backplane current requirement.
After installation, inspect the RUN, ERR, ETH MS, and ETH NS indicators to verify processor, module, port configuration, and network status.
For installations in ATEX or IECEx Zone 2/22 environments, apply the applicable hazardous-location installation requirements and certified system configuration.
Platba: T/T, Western Union.
Přístav odeslání: Xiamen.
Dodací lhůta: Obvykle 1–3 pracovní dny po potvrzení platby (v závislosti na skladových zásobách).
Celosvětové doručení: Dodáváme díly pro průmyslovou automatizaci zákazníkům po celém světě. Cena přepravy bude uvedena v naší nabídce na základě vaší poptávky.
Často kladené otázky
Časté otázky týkající se cenových nabídek, dopravy, záruky a vrácení zbožíNa stránce produktu klikněte na Požádat o cenovou nabídku a zašlete nám číslo dílu, požadované množství a cílovou zemi. Náš prodejní tým vám odpoví s informacemi o aktuální dostupnosti, ceně a odhadované době dodání.
Položky skladem se obvykle připravují po zaplacení a potvrzení objednávky. Většina objednávek se odesílá z našeho skladu v Číně, ačkoli místo odeslání se může lišit v závislosti na aktuálním stavu zásob.
Ano. Zasíláme díly pro průmyslovou automatizaci zákazníkům po celém světě. Náklady na dopravu a doba přepravy závisí na místě určení, hmotnosti zásilky, velikosti produktu a místních dovozních požadavcích.
Obvykle využíváme DHL, FedEx, UPS a další mezinárodní kurýrní služby. Dopravce lze vybrat podle místa určení, rychlosti doručení, velikosti zásilky a požadavků zákazníka.
Na naše výrobky se obecně vztahuje 12měsíční záruka. Způsobilé výrobky lze také vrátit v rámci našich 30denních podmínek pro vrácení peněz. Před vrácením jakékoli položky kontaktujte náš tým a ověřte si platné podmínky a pokyny k vrácení.
Mohlo by se vám také líbit
Příspěvky na blogu
Novinky z oblasti průmyslové automatizace, technické příručky a aktualizace produktů.