The Woodward 5441-695C Relay Output Module is a rack-mounted discrete output interface engineered for Woodward MicroNet and MicroNet Plus control platforms. It converts low-level controller logic into electrically isolated relay signals capable of driving field-level devices used in critical turbine, engine, and generator control systems.
As a later hardware revision within the 5441-695 family, the “C” version incorporates component updates and long-term reliability improvements while preserving electrical and functional compatibility with existing MicroNet architectures.
System Compatibility
The 5441-695C is designed for seamless integration with Woodward digital control systems, including:
- MicroNet Simplex
- MicroNet Plus
- Selected Woodward turbine and engine control platforms using MicroNet I/O architecture
The module supports direct mapping to discrete output logic without additional signal conditioning.
Relay Output Architecture
This module provides multiple mechanically isolated relay channels intended for safety-critical and operational control functions.
- Total Outputs: 16 independent relay channels
- Relay Configuration: Form-C contacts (SPDT), suitable for normally open or normally closed logic
-
Channel Isolation:
- Galvanic isolation between control electronics and field wiring
- Electrical separation between relay channels to reduce fault propagation
Typical control functions include shutdown actuation, permissive logic, alarm annunciation, and interlock signaling.
Electrical Specifications
The relay circuitry is designed for industrial load handling and noise immunity.
- Relay Coil Supply: 24 VDC (sourced internally by the control system)
-
Contact Capability:
- Rated for both resistive and inductive loads
- Suitable for solenoids, pilot relays, contactors, and alarm circuits
-
Protection Features:
- Arc suppression across contacts
- Internal isolation barriers to reduce EMI coupling
- Designed to meet turbine control reliability requirements
Exact contact ratings depend on application class and wiring practices but conform to Woodward MicroNet relay standards.
Mechanical & Interface Design
The 5441-695C is built as a plug-in I/O module for standard MicroNet racks.
- Mounting: Slot-mounted module for MicroNet chassis
- Controller Interface: Backplane or ribbon-cable connection (system dependent)
- Field Wiring: Removable terminal blocks for simplified installation and maintenance
- Cooling Method: Passive convection cooling
-
Construction:
- Industrial-grade PCB
- Socketed electromechanical relays for serviceability
Environmental & Reliability Characteristics
This module is intended for continuous operation in harsh industrial environments.
- Designed for high-vibration installations
- Stable performance under wide ambient temperature ranges typical of turbine enclosures
- Revision “C” hardware includes updated components selected for extended service life
- Suitable for mission-critical protection and shutdown logic
Typical Application Areas
The Woodward 5441-695C is commonly deployed in:
- Gas turbine control and protection systems
- Steam turbine sequencing and shutdown logic
- Compressor control panels
- Generator synchronization and auxiliary control
- Industrial safety shutdown and interlock systems
Related & Comparable Models
Within the same relay output family:
- 5441-695: Earlier hardware revisions with equivalent functionality
- 5441-691: Relay termination and interface variants for specific rack configurations
All variants share core MicroNet relay logic compatibility, with differences primarily in hardware revision and field termination style.
FAQ
Q: Can the 5441-695C replace earlier 5441-695 revisions? A: Yes. The “C” revision is backward-compatible with earlier versions and is commonly used as a direct replacement.
Q: Are the relay outputs safety-rated? A: The module is designed for safety-critical turbine applications but must be used within a properly engineered control system and safety architecture.
Q: Does this module require external power for relay coils? A: No. Relay coils are powered internally through the MicroNet control system.
Plaćanje: T/T, Western Union.
Luka otpreme: Siamen.
Rok isporuke: Obično 1–3 radna dana nakon potvrde uplate (u zavisnosti od zaliha).
Isporuka širom sveta: Šaljemo delove za industrijsku automatizaciju kupcima širom sveta. Troškovi prevoza se navode u vašem RFQ-u.
Česta pitanja (FAQ)
Najčešća pitanja o ponudama, isporuci, garanciji i povraćaju robeNa stranici proizvoda kliknite na Zatražite ponudu i pošaljite nam broj dela, potrebnu količinu i zemlju odredišta. Naš prodajni tim će odgovoriti informacijama o trenutnoj dostupnosti, ceni i procenjenom roku isporuke.
Artikli koji su na stanju obično se pripremaju nakon uplate i potvrde porudžbine. Većina porudžbina šalje se iz našeg skladišta u Kini, iako mesto slanja može da varira u zavisnosti od trenutnog stanja zaliha.
Da. Šaljemo delove za industrijsku automatizaciju kupcima širom sveta. Troškovi i vreme isporuke zavise od odredišta, težine paketa, veličine proizvoda i lokalnih uvoznih zahteva.
Najčešće koristimo DHL, FedEx, UPS i druge međunarodne kurirske službe. Prevoznik se može izabrati u skladu sa odredištem, brzinom isporuke, veličinom pošiljke i zahtevima kupca.
Naši proizvodi uglavnom imaju garanciju od 12 meseci. Proizvodi koji ispunjavaju uslove mogu se takođe vratiti u okviru naše politike povraćaja novca u roku od 30 dana. Obratite se našem timu pre vraćanja bilo kog artikla da biste potvrdili važeće uslove i uputstva za povraćaj.
Možda će vam se dopasti i
Blog objave
Vesti iz industrijske automatizacije, tehnički vodiči i novosti o proizvodima.